ArticleIEEE robotics and automation letters2017
Variable Damping Force Tunnel for Gait Training Using ALEX III.
Article in IEEE robotics and automation letters, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Variable Impedance Control Based on Target Position and Tracking Error for Rehabilitation Robots During a Reaching Task.Frontiers in neurorobotics · 2022Article
- ALICE: Conceptual Development of a Lower Limb Exoskeleton Robot Driven by an On-Board Musculoskeletal Simulator.Sensors (Basel, Switzerland) · 2020Article
- A Review of Robot-Assisted Lower-Limb Stroke Therapy: Unexplored Paths and Future Directions in Gait Rehabilitation.Frontiers in neurorobotics · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Haptic feedback affects not only the quality of training but can also influence the physical design of robotic gait trainers by determining how much force needs to be applied to the user and the nature of the force. This paper presents the design of a variable damping force tunnel and explores the effect of the shape and strength of the damping field using ALEX III, a treadmill-based exoskeleton developed at Columbia University. The study consists of 32 healthy subjects who were trained for 40 minutes in the device. The subjects were trained to follow a footpath with a 50% increase in step height, so the foot would have 1.5 times the ground clearance. Subjects were assigned to one of four groups: linear high, linear low, parabolic high, and parabolic low. Linear or parabolic denotes the shape of the damping field, and high or low denotes the rate of change (strength) of the field based on error. It is shown that the new controller is capable of inducing gait adaptations in healthy individuals while walking in the device. All groups showed adaptations in step height, while only the high strength groups showed changes in normalized error area, a measure of how closely the desired path was followed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.