Evidence map›Paper›PMID 29109636›Full record

ArticleJournal of anaesthesiology, clinical pharmacology

Comparison of polyvinyl chloride, curved reinforced, and straight reinforced endotracheal tubes for tracheal intubation through Airtraq™ laryngoscope in anesthetized patients.

Kush Ashokkumar Goyal, Shaji Mathew, Arun Kumar Handigodu Duggappa, Kanika P Nanda, Souvik Chaudhuri, Renganathan Sockalingam

Open access · diamondAbstract read
In one paragraph

Article in Journal of anaesthesiology, clinical pharmacology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kush Ashokkumar GoyalDepartment of Anaesthesiology, Kasturba Medical College, Manipal, Karnataka, India.
Shaji MathewDepartment of Anaesthesiology, Kasturba Medical College, Manipal, Karnataka, India.
Arun Kumar Handigodu DuggappaDepartment of Anaesthesiology, Kasturba Medical College, Manipal, Karnataka, India.
Kanika P NandaDepartment of Oral and Maxillofacial Surgery, Manipal College of Dental Sciences, Manipal, Karnataka, India.
Souvik ChaudhuriDepartment of Anaesthesiology, Kasturba Medical College, Manipal, Karnataka, India.
Renganathan SockalingamDepartment of Anaesthesiology, Kasturba Medical College, Manipal, Karnataka, India.
Kasturba Medical College, Manipal · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsThe Airtraq™ video laryngoscope facilitates tracheal intubations in patients with difficult airway or cervical spine immobilization. However, curved reinforced tracheal tube and straight reinforced tracheal tubes are useful where neck of the patient is likely to be moved or flexed or if patient is in prone position, wherein nonreinforced endotracheal tube (ETT) might get kinked and/or compressed. We compared intubation success rate of curved and straight reinforced tracheal tubes with polyvinyl chloride (PVC) tracheal tube using Airtaq™ laryngoscope in paralyzed and anesthetized patients. MATERIAL AND

methodsTotally, 120 patients underwent random allocation to one of the three groups using computer-generated randomization table. Patients were intubated with appropriate size and type of ETT using Airtraq™ after obtaining optimal glottis view. Experienced anesthesiologist performed endotracheal intubation and unblinded observer noted down success and ease of intubation.

resultsPatients intubated with PVC tube (100%) had higher rates of successful intubation and shorter intubation time (4 s), in comparison to intubation with curved reinforced (92.5%) and straight reinforced tubes (SRTs) (85%) using Airtraq™ laryngoscope (AL). However, there was no statistical difference in the incidence of airway trauma among all the three groups.

conclusionsPVC tracheal tube is significantly superior to both curved and SRTs for intubation using AL.

Indexed as

Airtraq™ laryngoscopeairway managementintubation

Identifiers

PMID29109636
PMCPMC5672516
OpenAlexW2755800001

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.