ReviewThe Cochrane database of systematic reviews2017
Interventions for treating central venous haemodialysis catheter malfunction.
Review in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 26 citations in OpenAlex.
- Treatment, characteristics and prognosis of central venous occlusion in hemodialysis patients with tunneled cuffed catheter dysfunction.Renal failure · 2026Article
- Clinical and Technical Factors Associated With Tunnelled Central Venous Catheter Dysfunction in Haemodialysis: A Multicentre Session-Level Retrospective Study.Nursing open · 2026Observational
- Standardized Episiotomy Using a Blade-Based Device Reduces Long-Term Perineal Pain and Improves Sexual Function: A Randomized Controlled Trial.International urogynecology journal · 2026Article
- A roundish dark spot in the upper cava vein.The journal of vascular access · 2025Article
- Predictive Tool for Tunnelled Central Venous Catheter Dysfunction in Haemodialysis.Journal of clinical medicine · 2025Article
- Complications of tunneled central venous catheter placement: a narrative review of risks, prevention, and management strategies.Frontiers in radiology · 2025Review
- Percutaneous transluminal angioplasty is safe and feasible for reinsertion of tunneled cuffed catheters in the right internal jugular vein.Scientific reports · 2024Article
- Article
- [Catheter Replacement Methods in Hemodialysis Patients With Dysfunctional Tunneled-Cuffed Catheters With Fibrin Sheaths].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2023Article
- Infectious outcomes of fibrin sheath disruption in tunneled dialysis catheters.The journal of vascular access · 2023Article
- Reduction in Thrombolytic Usage in Hemodialysis Patients Following a Quality Assurance Review: A Research Letter.Canadian journal of kidney health and disease · 2023Article
- Assessment of dysfunctional tunneled hemodialysis catheters and outcome of endovascular salvage techniques: a simple solution to a complex problem.Frontiers in cardiovascular medicine · 2023Article
- Locked Away-Prophylaxis and Management of Catheter Related Thrombosis in Hemodialysis.Journal of clinical medicine · 2021Review
- Long-Term Follow-Up and Clinical Relevance of Incidental Findings of Fibrin Sheath and Thrombosis on Computed Tomography Scans of Cancer Patients with Port Catheters.Therapeutics and clinical risk management · 2021Article
- Thrombolytic therapy for haemodialysis catheter dysfunction - value for money?Renal failure · 2020Article
- Efficacy and safety of secondary procedures for maintaining arteriovenous hemodialysis access patency: protocol for a systematic review and network meta-analysis.Systematic reviews · 2020Article
- Selective use of episiotomy: what is the impact on perineal trauma? Results from a retrospective cohort study.Archives of gynecology and obstetrics · 2020Article
- TuLIP (Tunnelled Line Intraluminal Plasty): An Alternative Technique for Salvaging Haemodialysis Catheter Patency in Fibrin Sheath Formation.Cardiovascular and interventional radiology · 2019Article
- Interventions for treating central venous haemodialysis catheter malfunction.The Cochrane database of systematic reviews · 2017Review
- Successful Removal and Replacement of a Stuck Hemodialysis Catheter via Thoracotomy: Report of Two Cases and Literature Review.Case reports in nephrology and dialysisArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAdequate haemodialysis (HD) in people with end-stage kidney disease (ESKD) is reliant upon establishment of vascular access, which may consist of arteriovenous fistula, arteriovenous graft, or central venous catheters (CVC). Although discouraged due to high rates of infectious and thrombotic complications as well as technical issues that limit their life span, CVC have the significant advantage of being immediately usable and are the only means of vascular access in a significant number of patients. Previous studies have established the role of thrombolytic agents (TLA) in the prevention of catheter malfunction. Systematic review of different thrombolytic agents has also identified their utility in restoration of catheter patency following catheter malfunction. To date the use and efficacy of fibrin sheath stripping and catheter exchange have not been evaluated against thrombolytic agents.
objectivesThis review aimed to evaluate the benefits and harms of TLA, preparations, doses and administration as well as fibrin-sheath stripping, over-the-wire catheter exchange or any other intervention proposed for management of tunnelled CVC malfunction in patients with ESKD on HD. SEARCH
methodsWe searched the Cochrane Kidney and Transplant Specialised Register up to 17 August 2017 through contact with the Information Specialist using search terms relevant to this review. Studies in the Specialised Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register (ICTRP) Search Portal, and ClinicalTrials.gov. SELECTION CRITERIA: We included all studies conducted in people with ESKD who rely on tunnelled CVC for either initiation or maintenance of HD access and who require restoration of catheter patency following late-onset catheter malfunction and evaluated the role of TLA, fibrin sheath stripping or over-the-wire catheter exchange to restore catheter function. The primary outcome was be restoration of line patency defined as ≥ 300 mL/min or adequate to complete a HD session or as defined by the study authors. Secondary outcomes included dialysis adequacy and adverse outcomes. DATA COLLECTION AND ANALYSIS: Two authors independently assessed retrieved studies to determine which studies satisfy the inclusion criteria and carried out data extraction. Included studies were assessed for risk of bias. Summary estimates of effect were obtained using a random-effects model, and results were expressed as risk ratios (RR) and their 95% confidence intervals (CI) for dichotomous outcomes, and mean difference (MD) and 95% CI for continuous outcomes. Confidence in the evidence was assessed using GRADE. MAIN
resultsOur search strategy identified 8 studies (580 participants) as eligible for inclusion in this review. Interventions included: thrombolytic therapy versus placebo (1 study); low versus high dose thrombolytic therapy (1); alteplase versus urokinase (1); short versus long thrombolytic dwell (1); thrombolytic therapy versus percutaneous fibrin sheath stripping (1); fibrin sheath stripping versus over-the-wire catheter exchange (1); and over-the-wire catheter exchange versus exchange with and without angioplasty sheath disruption (1). No two studies compared the same interventions. Most studies had a high risk of bias due to poor study design, broad inclusion criteria, low patient numbers and industry involvement.Based on low certainty evidence, thrombolytic therapy may restore catheter function when compared to placebo (149 participants: RR 4.05, 95% CI 1.42 to 11.56) but there is no data available to suggest an optimal dose or administration method. The certainty of this evidence is reduced due to the fact that it is based on only a single study with wide confidence limits, high risk of bias and imprecision in the estimates of adverse events (149 participants: RR 2.03, 95% CI 0.38 to 10.73).Based on the available evidence, physical disruption of a fibrin sheath using interventional radiology techniques appears to be equally efficacious as the use of a pharmaceutical thrombolytic agent for the immediate management of dysfunctional catheters (57 participants: RR 0.92, 95% CI 0.80 to 1.07).Catheter patency is poor following use of thrombolytic agents with studies reporting median catheter survival rates of 14 to 42 days and was reported to improve significantly by fibrin sheath stripping or catheter exchange (37 participants: MD -27.70 days, 95% CI -51.00 to -4.40). Catheter exchange was reported to be superior to sheath disruption with respect to catheter survival (30 participants: MD 213.00 days, 95% CI 205.70 to 220.30).There is insufficient evidence to suggest any specific intervention is superior in terms of ensuring either dialysis adequacy or reduced risk of adverse events. AUTHORS'
conclusionsThrombolysis, fibrin sheath disruption and over-the-wire catheter exchange are effective and appropriate therapies for immediately restoring catheter patency in dysfunctional cuffed and tunnelled HD catheters. On current data there is no evidence to support physical intervention over the use of pharmaceutical agents in the acute setting. Pharmacological interventions appear to have a bridging role and long-term catheter survival may be improved by fibrin sheath disruption and is probably superior following catheter exchange. There is no evidence favouring any of these approaches with respect to dialysis adequacy or risk of adverse events.The current review is limited by the small number of available studies with limited numbers of patients enrolled. Most of the studies included in this review were judged to have a high risk of bias and were potentially influenced by pharmaceutical industry involvement.Further research is required to adequately address the question of the most efficacious and clinically appropriate technique for HD catheter dysfunction.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.