Trial reportJournal of biomedical materials research. Part B, Applied biomaterials2018
Evaluation of central venous catheters coated with a noble metal alloy-A randomized clinical pilot study of coating durability, performance and tolerability.
Trial report in Journal of biomedical materials research. Part B, Applied biomaterials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 13 citations in OpenAlex.
- Evaluation of central venous catheters coated with a noble metal alloy-A randomized clinical pilot study of coating durability, performance and tolerability.Journal of biomedical materials research. Part B, Applied biomaterials · 2018Trial
- Antimicrobial Peptides in Preventive Medicine: Current Perspectives on Coating Strategies.ACS infectious diseases · 2026Review
- The current status and evolution of hemodialysis catheters.Renal failure · 2025Review
- Safety and complications of antimicrobial coated compared to conventional intramedullary femoral nails in proximal femoral fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Observational
- A novel noble metal stent coating reduces in vitro platelet activation and acute in vivo thrombosis formation: a blinded study.Scientific reports · 2023Article
- Phyto-assisted synthesis of zinc oxide nanoparticles for developing antibiofilm surface coatings on central venous catheters.Frontiers in chemistry · 2023Article
- Environmental, Microbiological, and Immunological Features of Bacterial Biofilms Associated with Implanted Medical Devices.Clinical microbiology reviews · 2022Review
- A Novel Device-Integrated Drug Delivery System for Local Inhibition of Urinary Tract Infection.Frontiers in microbiology · 2021Article
- Systematic Comparison of Epidemic and Non-Epidemic Carbapenem ResistantFrontiers in cellular and infection microbiology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The use of Central Venous Catheters (CVCs) commonly results in complications. Coatings with silver or metal alloys can reduce the risk associated with the use of CVC. We have evaluated the durability of a noble metal coated CVC (the Bactiguard Infectious Protection, BIP CVC) and compared with an uncoated CVC for clinical tolerability (Adverse Events, AEs) and performance, in order to create a baseline for a large future study. Patients undergoing major surgery, randomised at a 2:1 ratio to BIP CVC (n = 22) or standard CVC (n = 12), were catheterized 9 - 12 days, respectively. Adverse events, microbial colonization and metal release were measured.
findingsThere were no AEs in the BIP CVC-group, but 5 AEs occurred in 4 patients (1 patient had 2 AEs) in the standard CVC-group, p = 0.011 (whereof 3 were catheter related). The BIP CVC showed an initial release of coating metals in blood (gold, silver and palladium), which rapidly decreased and were far below Permitted Paily Exposure (PDE) for chronical use. The levels of silver concentration were far below those needed to develop microbial resistance. The performance was equal, and there was no difference concerning microbial colonization, for the two CVCs.
conclusionIn this pilot study the BIP CVC had significantly lower AEs and showed a comparable performance to the standard CVC. The coating was durable throughout the study length (up to 16 days) and toxicological evaluation showed good safety margins. Larger studies are needed. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2337-2344, 2018.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials