ReviewEpilepsia2017
Standards for data acquisition and software-based analysis of in vivo electroencephalography recordings from animals. A TASK1-WG5 report of the AES/ILAE Translational Task Force of the ILAE.
Review in Epilepsia, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 34 citations in OpenAlex.
- EEG CONNECT: A proposed reporting checklist for EEG-based connectivity studies in clinical epilepsy research.Epilepsia open · 2026Review
- Review
- Advances and challenges in experimental models of posttraumatic epilepsy for therapeutic interventions.Pharmacological reviews · 2025Review
- The role of electroencephalography in epilepsy research-From seizures to interictal activity and comorbidities.Epilepsia · 2025Review
- Review
- Article
- Increasing adult-born neurons protects mice from epilepsy.bioRxiv : the preprint server for biology · 2024Article
- Prospects of Electrocorticography in Neuropharmacological Studies in Small Laboratory Animals.Brain sciences · 2024Review
- Diffuse microglial responses and persistent EEG changes correlate with poor neurological outcome in a model of subarachnoid hemorrhage.Scientific reports · 2024Article
- A scalable platform for acquisition of high-fidelity human intracranial EEG with minimal clinical burden.PloS one · 2024Article
- A simple, automated method of seizure detection in mouse models of temporal lobe epilepsy.Epilepsy research · 2023Article
- Combining Multiple Psychophysiological Measures of Listening Effort: Challenges and Recommendations.Seminars in hearing · 2023Review
- Article
- Modulation of locomotor behaviors by location-specific epileptic spiking and seizures.Epilepsy & behavior : E&B · 2021Article
- Rodent EEG: Expanding the Spectrum of Analysis.Epilepsy currents · 2020Article
- Harmonization of the pipeline for seizure detection to phenotype post-traumatic epilepsy in a preclinical multicenter study on post-traumatic epileptogenesis.Epilepsy research · 2019Article
- Adult neurogenesis in the mouse dentate gyrus protects the hippocampus from neuronal injury following severe seizures.Hippocampus · 2019Article
- Article
- A companion to the preclinical common data elements and case report forms for rodent EEG studies. A report of the TASK3 EEG Working Group of the ILAE/AES Joint Translational Task Force.Epilepsia open · 2018Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 9 institutions in 4 countries.
Funding
Abstract
Electroencephalography (EEG)-the direct recording of the electrical activity of populations of neurons-is a tremendously important tool for diagnosing, treating, and researching epilepsy. Although standard procedures for recording and analyzing human EEG exist and are broadly accepted, there are no such standards for research in animal models of seizures and epilepsy-recording montages, acquisition systems, and processing algorithms may differ substantially among investigators and laboratories. The lack of standard procedures for acquiring and analyzing EEG from animal models of epilepsy hinders the interpretation of experimental results and reduces the ability of the scientific community to efficiently translate new experimental findings into clinical practice. Accordingly, the intention of this report is twofold: (1) to review current techniques for the collection and software-based analysis of neural field recordings in animal models of epilepsy, and (2) to offer pertinent standards and reporting guidelines for this research. Specifically, we review current techniques for signal acquisition, signal conditioning, signal processing, data storage, and data sharing, and include applicable recommendations to standardize collection and reporting. We close with a discussion of challenges and future opportunities, and include a supplemental report of currently available acquisition systems and analysis tools. This work represents a collaboration on behalf of the American Epilepsy Society/International League Against Epilepsy (AES/ILAE) Translational Task Force (TASK1-Workgroup 5), and is part of a larger effort to harmonize video-EEG interpretation and analysis methods across studies using in vivo and in vitro seizure and epilepsy models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.