Evidence map›Paper›PMID 29101536›Full record

ArticleMedical & biological engineering & computing2018

Vib-bracelet: a passive absorber for attenuating forearm tremor.

Eran Buki, Reuven Katz, Miriam Zacksenhouse, Ilana Schlesinger

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. [Design and analysis of human arm pathological tremor simulation system].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Design of a lightweight passive orthosis for tremor suppression.Journal of neuroengineering and rehabilitation · 2020
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Eran BukiMechanical Engineering Department, Technion Israel Institute for Technology, Haifa, Israel.
Reuven KatzMechanical Engineering Department, Technion Israel Institute for Technology, Haifa, Israel.
Miriam ZacksenhouseMechanical Engineering Department, Technion Israel Institute for Technology, Haifa, Israel. mermz@technion.ac.il.ORCID http://orcid.org/0000-0003-3022-5449
Ilana SchlesingerMovement Disorders Clinic, Department of Neurology, Rambam Medical Center, Haifa, Israel.

Funding

Technion-Israel Institute of Technology 2021850
6 · The paper itself

Abstract

Tremor is a rhythmic, involuntary, oscillatory movement of a limb produced by alternating contractions of reciprocally innervated muscles. More than 4% of the population over 40 years old suffer from tremor. There is no cure for most tremors, and while psychological therapy is sometimes helpful, tremors are usually treated with either medication or invasive surgery including thalamotomy and deep brain stimulation. Both medications and surgery may have adverse effects, and thus, there is a growing interest in developing non-invasive vibration attenuation devices. This paper presents a passive absorber device for attenuating pronation/supination tremor, dubbed Vib-bracelet. It is based on the principles of dynamic vibration absorption and is tuned to the frequency of the tremor. Prototypes were manufactured and tested on a mechanical model of the human forearm. Simulations and experiments demonstrate the efficiency of the device in attenuating vibrations in the range of 4-6 Hz, which is the range of frequency of observed tremor, with maximum amplitude attenuation of 85%.

Indexed as

VibrationAccelerationComputer SimulationForearmHumansParkinson DiseaseProne PositionSupine PositionTremorDynamic vibration absorberParkinson tremorPassive tremor attenuation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.