ReviewThe Journal of international medical research2018
Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review.
Review in The Journal of international medical research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 104 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
104 citing papers in PubMed, 1 synthesis or guideline pooled it, 229 citations in OpenAlex.
- The limit of tolerable micromotion for implant osseointegration: a systematic review.Scientific reports · 2021Pooled it
- TiNbSn stems with gradient changes of Young's modulus and stiffness reduce stress shielding compared to the standard fit-and-fill stems.European journal of medical research · 2023Trial
- Radiographic signs of implant loosening in sacroiliac joint fusion: an 11-year retrospective cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Toward next-generation hip implants: From failure mechanisms to translational design.Journal of orthopaedic translation · 2026Review
- The Geriatric Nutritional Risk Index Is an Independent Predictor of Prosthesis Aseptic Loosening in Patients Undergoing Total Joint Arthroplasty.Orthopaedic surgery · 2026Article
- GREM1 acts in leptin receptor-expressing skeletal cells to mediate peri-implant fibrosis.Nature communications · 2026Article
- An innovative hierarchical porous oxide surface with enhanced surface area for promoting early-stage bone regeneration potential.Journal of materials science. Materials in medicine · 2026Article
- A new anatomical locking plate for scapular neck fractures: a finite element analysis and retrospective clinical study.International orthopaedics · 2026Article
- Osseointegration of threaded acetabular cups - radiological and histological evaluation after total hip arthroplasty.International orthopaedics · 2026Article
- Article
- Anatomical implant region - a critical determinant for the osteogenic potency of small extracellular vesicles and rhBMP-2.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Article
- Bone-Ti-Alloy Interaction in Hip Arthroplasty of Patients with Diabetes, Dyslipidaemia, and Kidney Dysfunction: Three Case Reports and Brief Review.Medicina (Kaunas, Lithuania) · 2025Review
- Magnesium-containing implants enhance bone healing: A mechanobiological perspective.Mechanobiology in medicine · 2025Review
- Finite element analysis of bone remodeling induced by swelling anchors considering heterogeneous properties.Biomechanics and modeling in mechanobiology · 2025Article
- Conceptual Design and Additive Manufacturing of a Bidirectional Gradient Gyroid Structure for Tibial Stem.Annals of biomedical engineering · 2025Article
- Micropatterning and Nanodropletting of Titanium by Shifted Surface Laser Texturing Significantly Enhances In Vitro Osteogenesis of Healthy and Osteoporotic Mesenchymal Stromal Cells.Journal of functional biomaterials · 2025Article
- Prediction of bone ingrowth into the porous swelling bone anchors using an osteoconnectivity-based adaptive finite element algorithm.Medical & biological engineering & computing · 2025Article
- Is osteoporosis a contraindication for cementless total hip arthroplasty in younger patients? A matched cohort analysis of 71,578 patients.Journal of orthopaedics · 2025Article
- A Comparison ofHip & pelvis · 2025Article
- Physical activity and the risk of aseptic loosening after total hip arthroplasty: a case-control study from the Norwegian Arthroplasty Register.BMC musculoskeletal disorders · 2025Article
44 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hip osteoarthritis is the most common joint disorder, and is represented by a degenerative process, resulting in pain and functional impairment. If conservative treatment for hip osteoarthritis fails, the only remaining option is hip arthroplasty. Despite good survival of implants, loosening of components is the most common complication. This leads to revision surgeries, which are technically demanding, expensive, and result in a low satisfaction rate. Uncemented hip replacements require proper osseointegration for increased survival. Physical characteristics of implants include biocompatibility, Young's modulus of elasticity, strength, and corrosion resistance, and each influence fixation of implants. Moreover, implant surface treatments, pore size, pore density, and femoral stem design should be appropriately selected. Patients' optimization of obesity, osteoporosis, cardiovascular disease, psychotic disorders, and smoking cessation are associated with a higher survival of implants. Surgical factors, such as approach, drilling and rasping, acetabular bone coverage, acetabular cup positioning, and implant size, also affect survival of implants. Avoiding drugs, which may impair osseointegration of implants, and having an appropriate rehabilitation protocol are important. Future directions include anabolic and anti-catabolic bone-acting drugs to enhance osseointegration of implants. Comprehensive knowledge of the factors mentioned above is important for preventing aseptic loosening, with important socioeconomic consequences.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials