Evidence map›Paper›PMID 29098297›Full record

ArticleInvestigative ophthalmology & visual science2017

Retinal Vascular and Oxygen Temporal Dynamic Responses to Light Flicker in Humans.

Anthony E Felder, Justin Wanek, Norman P Blair, Mahnaz Shahidi

Open access · goldAbstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Anthony E FelderDepartment of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, United States.
Justin WanekDepartment of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, United States.
Norman P BlairDepartment of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, United States.
Mahnaz ShahidiDepartment of Ophthalmology, University of Southern California, Los Angeles, California, United States.
University of Illinois Chicago · USUniversity of Southern California · US

Funding

Translational Core for Therapeutic and Diagnostic DevelopmentP30EY001792 · NEI · UNIVERSITY OF ILLINOIS AT CHICAGO · PI MCANANY, JAMES JASON · 1985 to 2025
$14.8M
Ocular Biomarkers of Microvascular, Neural and Metabolic Function in DiabetesDP3DK104393 · NIDDK · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHAHIDI, MAHNAZ · 2014 to 2014
$1.5M
NEI NIH HHS P30 EY001792NIDDK NIH HHS DP3 DK104393
6 · The paper itself

Abstract

Purpose: To mathematically model the temporal dynamic responses of retinal vessel diameter (D), oxygen saturation (SO2), and inner retinal oxygen extraction fraction (OEF) to light flicker and to describe their responses to its cessation in humans. Methods: In 16 healthy subjects (age: 60 ± 12 years), retinal oximetry was performed before, during, and after light flicker stimulation. At each time point, five metrics were measured: retinal arterial and venous D (DA, DV) and SO2 (SO2A, SO2V), and OEF. Intra- and intersubject variability of metrics was assessed by coefficient of variation of measurements before flicker within and among subjects, respectively. Metrics during flicker were modeled by exponential functions to determine the flicker-induced steady state metric values and the time constants of changes. Metrics after the cessation of flicker were compared to those before flicker. Results: Intra- and intersubject variability for all metrics were less than 6% and 16%, respectively. At the flicker-induced steady state, DA and DV increased by 5%, SO2V increased by 7%, and OEF decreased by 13%. The time constants of DA and DV (14, 15 seconds) were twofold smaller than those of SO2V and OEF (39, 34 seconds). Within 26 seconds after the cessation of flicker, all metrics were not significantly different from before flicker values (P ≥ 0.07). Conclusions: Mathematical modeling revealed considerable differences in the time courses of changes among metrics during flicker, indicating flicker duration should be considered separately for each metric. Future application of this method may be useful to elucidate alterations in temporal dynamic responses to light flicker due to retinal diseases.

Indexed as

FemaleHealthy VolunteersHumansMaleMiddle AgedModels, TheoreticalOximetryOxygenOxygen ConsumptionPhotic StimulationRetinal VesselsVasodilationOxygen

Identifiers

PMID29098297
PMCPMC5678551
OpenAlexW2736413433

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.