Evidence map›Paper›PMID 29097945›Full record

ArticleContrast media & molecular imaging2017

Ventilation Series Similarity: A Study for Ventilation Calculation Using Deformable Image Registration and 4DCT to Avoid Motion Artifacts.

Geoffrey G Zhang, Kujtim Latifi, Vladimir Feygelman, Kuei-Ting Chou, Tzung-Chi Huang, Thomas J Dilling, Bradford A Perez, Eduardo G Moros

Open access · hybridAbstract read
In one paragraph

Article in Contrast media & molecular imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 82% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Geoffrey G ZhangRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.ORCID 0000-0001-8548-788X
Kujtim LatifiRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Vladimir FeygelmanRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Kuei-Ting ChouDepartment of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan.ORCID 0000-0003-3277-8338
Tzung-Chi HuangDepartment of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan.ORCID 0000-0001-5896-9170
Thomas J DillingRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Bradford A PerezRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Eduardo G MorosRadiation Oncology, Moffitt Cancer Center, Tampa, FL, USA.
Moffitt Cancer Center · USAsia University · TWChina Medical University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The major problem with ventilation distribution calculations using DIR and 4DCT is the motion artifacts in 4DCT. Quite often not all phases would exhibit mushroom motion artifacts. If the ventilation series similarity is sufficiently robust, the ventilation distribution can be calculated using only the artifact-free phases. This study investigated the ventilation similarity among the data derived from different respiration phases. Fifteen lung cancer cases were analyzed. In each case, DIR was performed between the end-expiration phase and all other phases. Ventilation distributions were then calculated using the deformation matrices. The similarity was compared between the series ventilation distributions. The correlation between the majority phases was reasonably good, with average SCC values between 0.28 and 0.70 for the original data and 0.30 and 0.75 after smoothing. The better correlation between the neighboring phases, with average SCC values between 0.55 and 0.70 for the original data, revealed the nonlinear property of the dynamic ventilation. DSC analysis showed the same trend. To reduce the errors if motion artifacts are present, the phases without serious mushroom artifacts may be used. To minimize the effect of the nonlinearity in dynamic ventilation, the calculation phase should be chosen as close to the end-inspiration as possible.

Indexed as

Respiration, ArtificialArtifactsFour-Dimensional Computed TomographyHumansLung NeoplasmsModels, TheoreticalMotion

Identifiers

PMID29097945
PMCPMC5623778
OpenAlexW2755021918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.