Evidence map›Paper›PMID 29089581›Full record

ArticleScientific reports2017

Central Blood Pressure Monitoring via a Standard Automatic Arm Cuff.

Keerthana Natarajan, Hao-Min Cheng, Jiankun Liu, Mingwu Gao, Shih-Hsien Sung, Chen-Huan Chen, Jin-Oh Hahn, Ramakrishna Mukkamala

Abstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Blood pressure measurements-Shifting the focus from periphery to center.Journal of clinical hypertension (Greenwich, Conn.) · 2020
    Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Keerthana NatarajanDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA.
Hao-Min ChengDepartment of Medicine, National Yang-Ming University, Taipei City, Taiwan.
Jiankun LiuDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA.
Mingwu GaoDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA.
Shih-Hsien SungDepartment of Medicine, National Yang-Ming University, Taipei City, Taiwan.
Chen-Huan Chen
Jin-Oh HahnDepartment of Mechanical Engineering, University of Maryland, College Park, MD, USA.ORCID 0000-0001-5429-2836
Ramakrishna MukkamalaDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA. rama@egr.msu.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current oscillometric devices for monitoring central blood pressure (BP) maintain the cuff pressure at a constant level to acquire a pulse volume plethysmography (PVP) waveform and calibrate it to brachial BP levels estimated with population average methods. A physiologic method was developed to further advance central BP measurement. A patient-specific method was applied to estimate brachial BP levels from a cuff pressure waveform obtained during conventional deflation via a nonlinear arterial compliance model. A physiologically-inspired method was then employed to extract the PVP waveform from the same waveform via ensemble averaging and calibrate it to the brachial BP levels. A method based on a wave reflection model was thereafter employed to define a variable transfer function, which was applied to the calibrated waveform to derive central BP. This method was evaluated against invasive central BP measurements from patients. The method yielded central systolic, diastolic, and pulse pressure bias and precision errors of -0.6 to 2.6 and 6.8 to 9.0 mmHg. The conventional oscillometric method produced similar bias errors but precision errors of 8.2 to 12.5 mmHg (p ≤ 0.01). The new method can derive central BP more reliably than some current non-invasive devices and in the same way as traditional cuff BP.

Indexed as

AgedArmArterial PressureBlood PressureBlood Pressure DeterminationBrachial ArteryFemaleHumansMaleMiddle AgedMonitoring, PhysiologicOscillometrySystole

Identifiers

PMID29089581
PMCPMC5663968

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked