ArticleChemistry Central journal2017
Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method.
Article in Chemistry Central journal, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 16 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundChronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality worldwide. A combination of indacaterol maleate with glycopyrronium bromide has recently been approved as a once-daily maintenance therapy in patients with COPD. The very low dose (μg level/capsule) renders the analysis of such products challenges. This study reports for the first time about HPLC method for the quality control of such combination and it is a stability indicating at the same time.
resultsA rapid, simple, precise and reproducible HPLC method was developed and validated for simultaneous determination of indacaterol maleate and glycopyrronium bromide using tenoxicam as an internal standard. The chromatographic separation was achieved on an onyx monolithic C18 column (100 × 4.6 mm) using a mobile phase consisting of acetonitrile and 30 mM phosphate buffer (pH 3.5) (30:70, v/v), run at a flow rate of 2 mL/min with UV detection at 210 nm. The total analysis time was less than 3 min. The HPLC method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 1-44 µg/mL for indacaterol maleate and 0.5-20 µg/mL for glycopyrronium bromide. Stability tests were done through exposure of the analyte solution for different stress conditions and the results indicate no interference of degradants with HPLC method.
conclusionsThe method was successfully applied for the quantitative analysis of indacaterol maleate and glycopyrronium bromide both individually and in a combined pharmaceutical inhaler capsules to support the quality control and to assure the therapeutic efficacy of the two drugs. The simple procedure involved in sample preparation and the short run-time added the important property of high throughput to the method. Graphical abstract Chemical structures and representative HPLC chromatogram of indacaterol maleate (IND; 22 μg/mL), glycopyrronium bromide (GLY; 10 μg/mL) and tenoxicam (IS, 15μg/mL) in commercial capsules.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.