ArticleAnnals of biomedical engineering2018

Role of Re-entry Tears on the Dynamics of Type B Dissection Flap.

Saranya Canchi, Xiaomei Guo, Matt Phillips, Zachary Berwick, Jarin Kratzberg, Joshua Krieger, Blayne Roeder, Stephan Haulon, Sean Chambers, Ghassan S Kassab

Open access · hybridAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. False lumen ejection fraction predicts growth in type B aortic dissection: preliminary results.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2020
    Observational
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Saranya CanchiCalifornia Medical Innovations Institute, 11107 Roselle St., Rm. 211, San Diego, CA, 92121, USA.
Xiaomei GuoCalifornia Medical Innovations Institute, 11107 Roselle St., Rm. 211, San Diego, CA, 92121, USA.
Matt Phillips3DT holdings LLC, San Diego, CA, USA.
Zachary Berwick3DT holdings LLC, San Diego, CA, USA.
Jarin KratzbergCook Medical Inc, Bloomington, IN, USA.
Joshua KriegerCook Medical Inc, Bloomington, IN, USA.
Blayne RoederCook Medical Inc, Bloomington, IN, USA.
Stephan HaulonAortic Center, Hôpital Cardiologique, CHU de Lille, Lille, France.
Sean ChambersCook Medical Inc, Bloomington, IN, USA.
Ghassan S KassabCalifornia Medical Innovations Institute, 11107 Roselle St., Rm. 211, San Diego, CA, 92121, USA. gkassab@calmi2.org.
Cook Medical (United States) · USCalifornia Medical Innovations Institute · US3DT Holdings (United States) · USLille’s Cardiology Hospital · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mortality during follow-up after acute Type B aortic dissection is substantial with aortic expansion observed in over 59% of the patients. Lumen pressure differential is considered a prime contributing factor for aortic dilation after propagation. The objective of the study was to evaluate the relationship between changes in vessel geometry with and without lumen pressure differential post propagation in an ex vivo porcine model with comparison with patient clinical data. A pulse duplicator system was utilized to propagate the dissection within descending thoracic porcine aortic vessels for set proximal (%circumference of the entry tear: 40%, axial length: 2 cm) and re-entry (50% of distal vessel circumference) tear geometry. Measurements of lumen pressure differential were made along with quantification of vessel geometry (n = 16). The magnitude of mean lumen pressure difference measured after propagation was low (~ 5 mmHg) with higher pressures measured in false lumen and as anticipated the pressure difference approached zero after the creation of distal re-entry tear. False lumen Dissection Ratio (FDR) defined as arc length of dissected wall divided by arc length of dissection flap, had mean value of 1.59 ± 0.01 at pressure of 120/80 mmHg post propagation with increasing values with increase in pulse pressure that was not rescued with the creation of distal re-entry tear (p < 0.01). An average FDR of 1.87 ± 0.27 was measured in patients with acute Type B dissection. Higher FDR value (FDR = 1 implies zero dissection) in the presence of distal re-entry tear demonstrates an acute change in vessel morphology in response to the dissection independent of local pressure changes challenges the re-apposition of the aortic wall.

Indexed as

AdultAgedAnimalsAortic Aneurysm, ThoracicAortic DissectionFemaleHumansMaleMiddle AgedSwineAcute aortic dissectionClinical FDRDilationEx vivo modelLumen pressureStrain

Identifiers

PMID29086223
PMCPMC5754433
OpenAlexW2766209442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.