ArticleJournal of the Association for Research in Otolaryngology : JARO2018
Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear Implant Users: Effects of Stimulation Mode.
Article in Journal of the Association for Research in Otolaryngology : JARO, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Evaluating and Comparing Behavioural and Electrophysiological Estimates of Neural Health in Cochlear Implant Users.Journal of the Association for Research in Otolaryngology : JARO · 2021Article
- Cochlear implants and other inner ear prostheses: today and tomorrow.Current opinion in physiology · 2020Article
- Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation.Hearing research · 2020Article
- Investigation of Electrically Evoked Auditory Brainstem Responses to Multi-Pulse Stimulation of High Frequency in Cochlear Implant Users.Frontiers in neuroscience · 2020Article
- Pulse-rate discrimination deficit in cochlear implant users: is the upper limit of pitch peripheral or central?Hearing research · 2019Article
- Musical Sound Quality as a Function of the Number of Channels in Modern Cochlear Implant Recipients.Frontiers in neuroscience · 2019Article
- Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners.Journal of the Association for Research in Otolaryngology : JARO · 2018Article
- Current Focusing to Reduce Channel Interaction for Distant Electrodes in Cochlear Implant Programs.Trends in hearingArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Previous psychophysical studies have shown that a steep detection-threshold-versus-stimulation-rate function (multipulse integration; MPI) is associated with laterally positioned electrodes producing a broad neural excitation pattern. These findings are consistent with steep MPI depending on either a certain width of neural excitation allowing a large population of neurons operating at a low point on their dynamic range to respond to an increase in stimulation rate or a certain slope of excitation pattern that allows recruitment of neurons at the excitation periphery. Results of the current study provide additional support for these mechanisms by demonstrating significantly flattened MPI functions in narrow bipolar than monopolar stimulation. The study further examined the relationship between the steepness of the psychometric functions for detection (d' versus log current level) and MPI. In contrast to findings in monopolar stimulation, current data measured in bipolar stimulation suggest that steepness of the psychometric functions explained a moderate amount of the across-site variance in MPI. Steepness of the psychometric functions, however, cannot explain why MPI flattened in bipolar stimulation, since slopes of the psychometric functions were comparable in the two stimulation modes. Lastly, our results show that across-site mean MPI measured in monopolar and bipolar stimulation correlated with speech recognition in opposite signs, with steeper monopolar MPI being associated with poorer performance but steeper bipolar MPI being associated with better performance. If steeper MPI requires broad stimulation of the cochlea, the correlation between monopolar MPI and speech recognition can be interpreted as the detrimental effect of poor spectral resolution on speech recognition. Assuming bipolar stimulation produces narrow excitation, and MPI measured in bipolar stimulation reflects primarily responses of the on-site neurons, the correlation between bipolar MPI and speech recognition can be understood in light of the importance of neural survival for speech recognition.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.