Evidence map›Paper›PMID 29080274›Full record

ArticleMedical physics2018

Low-dose CT perfusion with projection view sharing.

Thomas Martin, John Hoffman, Jeff R Alger, Michael McNitt-Gray, Danny Jj Wang

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Low Dose CT Perfusion With K-Space Weighted Image Average (KWIA).IEEE transactions on medical imaging · 2020
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Thomas MartinDepartment of Neurology, University of California Los Angeles, Los Angeles, CA, USA.
John HoffmanDepartment of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA.
Jeff R AlgerDepartment of Neurology, University of California Los Angeles, Los Angeles, CA, USA.
Michael McNitt-GrayDepartment of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA.
Danny Jj WangDepartment of Neurology, University of California Los Angeles, Los Angeles, CA, USA.
University of California, Los Angeles · USUniversity of Southern California · US

Funding

Non-contrast 4-D Dynamic MRA in Arteriovenous Malformation (AVM)R01EB014922 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI WANG, DANNY JJ · 2013 to 2016
$1.8M
Novel Algorithms for Reducing Radiation Dose of CT PerfusionR44EB024438 · NIBIB · HURA IMAGING, INC · PI ALGER, JEFFRY R, WANG, DANNY JJ · 2020 to 2021
$1.6M
A Novel System for Reducing Radiation Dose of CT PerfusionR41EB024438 · NIBIB · HURA IMAGING, INC · PI WANG, DANNY JJ · 2017 to 2017
$266k
NIBIB NIH HHS R01 EB014922NIBIB NIH HHS R41 EB024438NIBIB NIH HHS R44 EB024438
6 · The paper itself

Abstract

purposeCT Perfusion (CTP) is a widely used clinical imaging modality. However, CTP typically involves the use of substantial radiation dose (CTDI

methodsThe KWIC reconstruction is based on an angle-bisection scheme. In KWIC, a Fourier transform was performed along each projection to form a "k-space"-like CT data space, based on the central-slice theorem. As a projection view-sharing technique, KWIC preserves the spatiotemporal resolution of undersampled CTP data by progressively increasing the number of projection views shared for more distant regions of "k-space". KWIC reconstruction was evaluated on a digital FORBILD head phantom with numerically simulated time-varying objects. The numerically simulated scans were undersampled using the angle-bisection scheme to achieve 50%, 25%, and 12.5% of the original dose (288, 144, and 72 projections, respectively). The area-under-the-curve (AUC), time-to-peak (TTP), and full width half maximum (FWHM) were measured in KWIC recons and compared to fully sampled filtered back projection (FBP) reconstructions. KWIC reconstruction and dose reduction was also implemented for three clinical CTP cases (45 s, 1156 projections per turn, 1 s/turn, CTDI

resultsThe AUC, TTP, and FWHM in the numerical simzulations were unaffected by the undersampling/dose reduction (down to 12.5% dose) with KWIC reconstruction compared to the fully sampled FBP reconstruction. The normalized root-mean-square-error (NRMSE) of the AUC in the FORBILD head phantom is 0.04, 0.05, and 0.07 for 50%, 25%, and 12.5% KWIC, respectively, as compared to FBP reconstruction. The cerebral blood flow (CBF) and cerebral blood volume had no significant difference between FBP and 50%, 25%, and 12.5% KWIC reconstructions (P > 0.05).

conclusionsThis study demonstrates that KWIC preserves perfusion metrics for CTP with substantially reduced dose. Clinical implementation will require further investigation into methods of rapid switching of a CT x-ray source.

Indexed as

Radiation DosageImage Processing, Computer-AssistedPerfusion ImagingTomography, X-Ray ComputedCT perfusionfiltered back projection (FBP)k-space weighted image contrast (KWIC)projection view sharing

Identifiers

PMID29080274
PMCPMC5774228
OpenAlexW2766987475

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.