Evidence map›Paper›PMID 29074938›Full record

ArticleScientific reports2017

Label-free analysis of the characteristics of a single cell trapped by acoustic tweezers.

Min Gon Kim, Jinhyoung Park, Hae Gyun Lim, Sangpil Yoon, Changyang Lee, Jin Ho Chang, K Kirk Shung

Abstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Article
  3. Pressure estimation of ultra-high frequency ultrasound using gas vesicles.The Journal of the Acoustical Society of America · 2024
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Methods to mechanically perturb and characterize GUV-based minimal cell models.Computational and structural biotechnology journal · 2023
    Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Holographic acoustic tweezers.Proceedings of the National Academy of Sciences of the United States of America · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Min Gon KimDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA.
Jinhyoung ParkDepartment of Biomedical Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do, 16419, Republic of Korea.
Hae Gyun LimDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA.
Sangpil YoonDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA.
Changyang LeeDepartment of Biomedical Engineering, Sogang University, Seoul, 04107, Republic of Korea.
Jin Ho ChangDepartment of Biomedical Engineering, Sogang University, Seoul, 04107, Republic of Korea. jhchang@sogang.ac.kr.ORCID 0000-0002-8323-4202
K Kirk ShungDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA.

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
Acoustic-transfection using high frequency ultrasound for intracellular delivery of macromolecules into targeted single cellsK99GM120493 · NIGMS · UNIVERSITY OF SOUTHERN CALIFORNIA · PI YOON, SANGPIL · 2017 to 2018
$124k
NIBIB NIH HHS P41 EB002182NIGMS NIH HHS K99 GM120493
6 · The paper itself

Abstract

Single-cell analysis is essential to understand the physical and functional characteristics of cells. The basic knowledge of these characteristics is important to elucidate the unique features of various cells and causative factors of diseases and determine the most effective treatments for diseases. Recently, acoustic tweezers based on tightly focused ultrasound microbeam have attracted considerable attention owing to their capability to grab and separate a single cell from a heterogeneous cell sample and to measure its physical cell properties. However, the measurement cannot be performed while trapping the target cell, because the current method uses long ultrasound pulses for grabbing one cell and short pulses for interrogating the target cell. In this paper, we demonstrate that short ultrasound pulses can be used for generating acoustic trapping force comparable to that with long pulses by adjusting the pulse repetition frequency (PRF). This enables us to capture a single cell and measure its physical properties simultaneously. Furthermore, it is shown that short ultrasound pulses at a PRF of 167 kHz can trap and separate either one red blood cell or one prostate cancer cell and facilitate the simultaneous measurement of its integrated backscattering coefficient related to the cell size and mechanical properties.

Indexed as

Biomechanical PhenomenaBlood CellsCell Line, TumorCell SizeCell SurvivalEquipment DesignHumansMaleMicroscopy, FluorescencePolystyrenesProstatic NeoplasmsSingle-Cell AnalysisUltrasonicsPolystyrenes

Identifiers

PMID29074938
PMCPMC5658370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.