Evidence map›Paper›PMID 29074268›Full record

ArticleInternational journal of hygiene and environmental health2018

Waterpipe cafés are hazardous to your health: Determination of a waterpipe specific calibration factor.

Mark J Travers, Jessica A Kulak, Lisa Vogl

Open access · greenAbstract read
In one paragraph

Article in International journal of hygiene and environmental health, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Indoor air quality in waterpipe cafés: exposure level to particulate matter.Environmental science and pollution research international · 2019
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Mark J TraversDepartment of Health Behavior and Air Pollution Exposure Research Laboratory, Roswell Park Cancer Institute, Buffalo, NY, USA. Electronic address: Mark.Travers@roswellpark.org.
Jessica A KulakDepartment of Health Behavior and Air Pollution Exposure Research Laboratory, Roswell Park Cancer Institute, Buffalo, NY, USA; Primary Care Research Institute, Department of Family Medicine, University at Buffalo, The State University of New York, Buffalo, NY, USA.
Lisa VoglDepartment of Health Behavior and Air Pollution Exposure Research Laboratory, Roswell Park Cancer Institute, Buffalo, NY, USA.
Roswell Park Comprehensive Cancer Center · US

Funding

Two-Spirit Films in Indigenous Cancer HealthP30CA016056 · NCI · ROSWELL PARK CANCER INSTITUTE CORP · PI Christine B. Ambrosone · 1985 to 2026
$116.6M
NCI NIH HHS P30 CA016056
6 · The paper itself

Abstract

introductionThe use of a waterpipe to smoke tobacco has emerged as a popular trend in the United States. Waterpipe smoking establishments have had an increasing presence in the U.S., despite smoke-free air legislation. Dangers of waterpipe smoking have been documented, but less data has been gathered about the waterpipe café itself. This project sought to determine a waterpipe-specific calibration factor (CF) for measuring waterpipe aerosol, and field-test this CF by conducting surveillance on the existing waterpipe cafés of western and central New York.

methodsNine laboratory-controlled experiments were conducted to determine a waterpipe-specific CF. In the lab, two TSI SidePak AM510 Personal Aerosol Monitors and two sampling trains for gravimetric PM

resultsResults from the 9 controlled waterpipe experiments determined a calibration factor of 0.38 (SD 0.08), which should be used to convert SidePak measurements to true PM

conclusionsApplying the waterpipe-specific CF for the SidePak, 0.38, allowed for field assessments to be conducted in locations with waterpipe smoke to determine accurate particle exposure concentrations. The concentrations of both particulate matter and carbon monoxide were above established air quality standards and therefore increase the health risks of both patrons and workers of these establishments.

Indexed as

Water Pipe SmokingTobacco Smoke PollutionTobacco Smoke PollutionCalibration factorIndoor air qualityParticulate matterPM(2.5)Waterpipe

Identifiers

PMID29074268
PMCPMC10860648
OpenAlexW2763286206

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.