Evidence map›Paper›PMID 29073228›Full record

ArticlePloS one2017

Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T.

Ladislav Valkovič, Iulius Dragonu, Salam Almujayyaz, Alex Batzakis, Liam A J Young, Lucian A B Purvis, William T Clarke, Tobias Wichmann, Titus Lanz, Stefan Neubauer and 3 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 43 citations in OpenAlex.

  1. Repeatability of Rapid Human Cardiac Phosphorus MRSI (Magnetic resonance in medicine · 2026
    Article
  2. NMR in biomedicine · 2026
    Article
  3. Article
  4. Development of a Double TunedNMR in biomedicine · 2025
    Article
  5. Fast 3DMagnetic resonance in medicine · 2025
    Article
  6. Fast 3DArXiv · 2024
    Article
  7. CardiacHeart failure reviews · 2023
    Review
  8. Article
  9. Article
  10. Dual-Tuned Lattice Balun for Multi-Nuclear MRI and MRS.IEEE transactions on medical imaging · 2022
    Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. PCA denoising and Wiener deconvolution ofMagnetic resonance in medicine · 2021
    Article
  16. A 16-ChannelIEEE transactions on bio-medical engineering · 2021
    Article
  17. Feasibility ofNMR in biomedicine · 2021
    Article
  18. Article
  19. 7T MR Safety.Journal of magnetic resonance imaging : JMRI · 2021
    Article
  20. RF Coil Setup forFrontiers in neurology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 4 institutions in 3 countries.

Ladislav ValkovičOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.ORCID http://orcid.org/0000-0003-2567-3642
Iulius DragonuSiemens Healthcare Limited, Frimley, United Kingdom.
Salam AlmujayyazMR Coils BV, Zaltbommel, Netherlands.
Alex BatzakisMR Coils BV, Zaltbommel, Netherlands.
Liam A J YoungOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
Lucian A B PurvisOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
William T ClarkeOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
Tobias WichmannRapid Biomedical GmbH, Rimpar, Germany.
Titus LanzRapid Biomedical GmbH, Rimpar, Germany.
Stefan NeubauerOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
Matthew D RobsonOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
Dennis W J KlompMR Coils BV, Zaltbommel, Netherlands.
Christopher T RodgersOxford Centre for Clinical Magnetic Resonance Research (OCMR), BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom.
University of Oxford · GBSiemens (United Kingdom) · GBSlovak Academy of Sciences · SKUniversity Medical Center Utrecht · NL

Funding

Medical Research Council G0900883Wellcome Trust
6 · The paper itself

Abstract

purposeCardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter) transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS. MATERIALS AND

methodsA fully-removable (55 cm diameter) birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany). Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers.

resultsThe combined (volume-transmit, local receive array) setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum) compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%); and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr) maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable.

conclusionThis easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T.

Indexed as

HeartHumansMagnetic Resonance ImagingPhosphorus IsotopesSignal-To-Noise RatioPhosphorus Isotopes

Identifiers

PMID29073228
PMCPMC5658155
OpenAlexW2766705177

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.