Evidence map›Paper›PMID 29067562›Full record

ArticleAnnals of biomedical engineering2018

Knee Implant Loosening Detection: A Vibration Analysis Investigation.

Arash Arami, Jean-Romain Delaloye, Hossein Rouhani, Brigitte M Jolles, Kamiar Aminian

Open access · hybridAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 3 countries.

Arash AramiLaboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland. a.arami@imperial.ac.uk.ORCID http://orcid.org/0000-0001-7609-6553
Jean-Romain DelaloyeCentre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland.
Hossein RouhaniLaboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
Brigitte M JollesCentre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland.
Kamiar AminianLaboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
University Hospital of Lausanne · CHÉcole Polytechnique Fédérale de Lausanne · CHImperial College London · GBUniversity of Alberta · CA

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CH) SNF20NAN1_123630
6 · The paper itself

Abstract

Knee implant loosening is mainly caused by the weakness of the prosthesis-bone interface and is the main reason for surgical revisions. However, pre-operative diagnosis is difficult due to lack of accurate tests. In this study, we developed a vibration-based system to detect the loosening of the tibial implant of an instrumented knee prosthesis. The proposed system includes an instrumented vibrator for transcutaneous stimulation of the bone in a repeatable manner, and accelerometer sensors integrated into the implants to measure the propagated vibration. A coherence-based detection technique was proposed to distinguish the loosened implants from the secure ones. Fourteen ex vivo lower limbs were used, on which the knee prosthesis was implanted, and harmonic-forced vibration was applied on the tibia. The input-output coherence measure provided 92.26% accuracy, a high sensitivity (91.67%) and specificity (92.86%). This technique was benchmarked against power spectrum based analysis of the propagated vibration to the implant. In particular, loosening detection based on new peak appearance, peak shift, and peak flattening in power spectra showed inferior performance to the proposed coherence-based technique. As such, application of vibration on our instrumented knee prosthesis together with input-output coherence analysis enabled us to distinguish the secure from loose implants.

Indexed as

Knee ProsthesisProsthesis FailureAccelerometryAgedAged, 80 and overFemaleHumansLower ExtremityMaleMiddle AgedSignal Processing, Computer-AssistedTibiaVibrationImplant looseningInput–output coherenceKnee prosthesisPower spectrum densityVibration analysis

Identifiers

PMID29067562
PMCPMC5754435
OpenAlexW2766047645

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.