ArticleJournal of healthcare engineering2017
Experimental Study on the Mechanical Properties of Porcine Cartilage with Microdefect under Rolling Load.
Article in Journal of healthcare engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 8 citations in OpenAlex.
- An in silico mechanoregulatory model of depth-dependent adaptations to mechanical loading in intact and damaged cartilage: a proof of concept study.Biomechanics and modeling in mechanobiology · 2025Article
- AnFrontiers in bioengineering and biotechnology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo investigate the mechanical responses of microdefect articular cartilage under rolling load and find out the failure rule.
methodsRolling load was applied to the porcine articular cartilage samples with rectangular notches of different depths. The displacement and strain near the notches were obtained by the noncontact digital image correlation technique.
resultsThe strain value and peak frequency around the notch increased; the maximum equivalent strain value could be observed at both bottom corners of the notch; the equivalent strain value first increased and then decreased at the points in the superficial and middle layers with the increase of rolling velocity; the points in the deep layer were less affected by rolling velocity; the equivalent strain value of the points in the superficial layer declined after rising with the increase of defect depth, while a decreased trend could be found for the points in the middle and deep layers.
conclusionsThe shear strain, which rose with the increase in defect depth, was the main factor in cartilage destruction. The cartilage tended to be destructed firstly at the bottom corner of the defect. Rolling velocity showed significant effects on superficial and middle layers. Cartilage had the ability to resist destruction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.