ArticleMedical physics2018
Quantitative imaging of peripheral trabecular bone microarchitecture using MDCT.
Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04518722 (CT-Based Changes in Bone and Marrow Among Patients on Oral Steroids), which is not on this map. Cited by 32 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
CT-Based Changes in Bone and Marrow Among Patients on Oral Steroids
Who cites it
32 citing papers in PubMed, 51 citations in OpenAlex.
- Standardization of bone mineral density and microstructure from high-resolution CT-scans of the spine in a multicenter setting.Zeitschrift fur medizinische Physik · 2026Article
- High-resolution peripheral quantitative computed tomography reliability and accuracy of bone density and morphology properties in children.JBMR plus · 2025Article
- Associations between longitudinal fluoride intakes from birth to age 23 and multi-row detector computed tomography bone densitometry outcomes at age 23.Journal of public health dentistry · 2024Article
- Ultra-low dose hip CT-based automated measurement of volumetric bone mineral density at proximal femoral subregions.Medical physics · 2024Article
- Deep learning-based harmonization of trabecular bone microstructures between high- and low-resolution CT imaging.Medical physics · 2024Article
- Biomechanics of the Human Osteochondral Unit: A Systematic Review.Materials (Basel, Switzerland) · 2024Review
- Preserving Trabecular Bone Structure in Gross Specimens with Paraffin Wax for the Study of Osteoporosis.Journal of plastination · 2024Article
- A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images.Radiology. Artificial intelligence · 2023Article
- Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography.Diagnostics (Basel, Switzerland) · 2023Article
- Continuum finite element analysis generalizesBiomedical physics & engineering express · 2023Article
- The association between paraspinal muscle degeneration and osteoporotic vertebral compression fracture severity in postmenopausal women.Journal of back and musculoskeletal rehabilitation · 2023Article
- Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT.Zeitschrift fur medizinische Physik · 2022Article
- Computed Tomography-Based Stiffness Measures of Trabecular Bone Microstructure: Cadaveric Validation and In Vivo Application.JBMR plus · 2022Article
- Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling.Medical physics · 2022Article
- Generation of Vertebra Micro-CT-like Image from MDCT: A Deep-Learning-Based Image Enhancement Approach.Tomography (Ann Arbor, Mich.) · 2021Article
- Quantitative CT-Based Methods for Bone Microstructural Measures and Their Relationships With Vertebral Fractures in a Pilot Study on Smokers.JBMR plus · 2021Article
- Article
- High-Density Mineralized Protrusions and Central Osteophytes: Associated Osteochondral Junction Abnormalities in Osteoarthritis.Diagnostics (Basel, Switzerland) · 2020Article
- A comparative study of trabecular bone micro-structural measurements using different CT modalities.Physics in medicine and biology · 2020Article
- Bone structure determined by HR-MDCT does not correlate with micro-CT of lumbar vertebral biopsies: a prospective cross-sectional human in vivo study.Journal of orthopaedic surgery and research · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
Abstract
purposeOsteoporosis associated with reduced bone mineral density (BMD) and microarchitectural changes puts patients at an elevated risk of fracture. Modern multidetector row CT (MDCT) technology, producing high spatial resolution at increasingly lower dose radiation, is emerging as a viable modality for trabecular bone (Tb) imaging. Wide variation in CT scanners raises concerns of data uniformity in multisite and longitudinal studies. A comprehensive cadaveric study was performed to evaluate MDCT-derived Tb microarchitectural measures. A human pilot study was performed comparing continuity of Tb measures estimated from two MDCT scanners with significantly different image resolution features.
methodMicro-CT imaging of cadaveric ankle specimens (n=25) was used to examine the validity of MDCT-derived Tb microarchitectural measures. Repeat scan reproducibility of MDCT-based Tb measures and their ability to predict mechanical properties were examined. To assess multiscanner data continuity of Tb measures, the distal tibias of 20 volunteers (age:26.2±4.5Y,10F) were scanned using the Siemens SOMATOM Definition Flash and the higher resolution Siemens SOMATOM Force scanners with an average 45-day time gap between scans. The correlation of Tb measures derived from the two scanners over 30% and 60% peel regions at the 4% to 8% of distal tibia was analyzed.
resultsMDCT-based Tb measures characterizing bone network area density, plate-rod microarchitecture, and transverse trabeculae showed good correlations (r∈0.85,0.92) with the gold standard micro-CT-derived values of matching Tb measures. However, other MDCT-derived Tb measures characterizing trabecular thickness and separation, erosion index, and structure model index produced weak correlation (r<0.8) with their micro-CT-derived values. Most MDCT Tb measures were found repeatable (ICC∈0.94,0.98). The Tb plate-width measure showed a strong correlation (r = 0.89) with experimental yield stress, while the transverse trabecular measure produced the highest correlation (r = 0.81) with Young's modulus. The data continuity experiment showed that, despite significant differences in image resolution between two scanners (10% MTF along xy-plane and z-direction - Flash: 16.2 and 17.9 lp/cm; Force: 24.8 and 21.0 lp/cm), most Tb measures had high Pearson correlations (r > 0.95) between values estimated from the two scanners. Relatively lower correlation coefficients were observed for the bone network area density (r = 0.91) and Tb separation (r = 0.93) measures.
conclusionMost MDCT-derived Tb microarchitectural measures are reproducible and their values derived from two scanners strongly correlate with each other as well as with bone strength. This study has highlighted those MDCT-derived measures which show the greatest promise for characterization of bone network area density, plate-rod and transverse trabecular distributions with a good correlation (r ≥ 0.85) compared with their micro-CT-derived values. At the same time, other measures representing trabecular thickness and separation, erosion index, and structure model index produced weak correlations (r < 0.8) with their micro-CT-derived values, failing to accurately portray the projected trabecular microarchitectural features. Strong correlations of Tb measures estimated from two scanners suggest that image data from different scanners can be used successfully in multisite and longitudinal studies with linear calibration required for some measures. In summary, modern MDCT scanners are suitable for effective quantitative imaging of peripheral Tb microarchitecture if care is taken to focus on appropriate quantitative metrics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.