Evidence map›Paper›PMID 29064579›Full record

ArticleMedical physics2018

Quantitative imaging of peripheral trabecular bone microarchitecture using MDCT.

Cheng Chen, Xiaoliu Zhang, Junfeng Guo, Dakai Jin, Elena M Letuchy, Trudy L Burns, Steven M Levy, Eric A Hoffman, Punam K Saha

Registry-linked trialOpen access · greenAbstract readValidation Study
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04518722 (CT-Based Changes in Bone and Marrow Among Patients on Oral Steroids), which is not on this map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04518722 terminatednot on this mapstarted 2020, after this paper: background citation

CT-Based Changes in Bone and Marrow Among Patients on Oral Steroids

TypeobservationalSponsorUniversity of IowaRan2020 to 2021Enrolled2ConditionsAsthma, Bone Density, Low, Oral Steroid-Dependent Asthma (Disorder)ArmsCT Scan, DXA Scan, Steroid Intake Questionnaire
3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Continuum finite element analysis generalizesBiomedical physics & engineering express · 2023
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Cheng ChenDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, USA.
Xiaoliu ZhangDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, USA.
Junfeng GuoDepartment of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, USA.
Dakai JinDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, USA.
Elena M LetuchyDepartment of Epidemiology, College of Public Health, University of Iowa, Iowa City, IA, USA.
Trudy L BurnsDepartment of Epidemiology, College of Public Health, University of Iowa, Iowa City, IA, USA.
Steven M LevyDepartment of Epidemiology, College of Public Health, University of Iowa, Iowa City, IA, USA.
Eric A HoffmanDepartment of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, USA.
Punam K SahaDepartment of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, USA.
University of Iowa · US

Funding

Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI HANS-JOACHIM LEHMLER · 1990 to 2026
$40.5M
UNIVERSITY OF IOWA CTSA FOR PEDIATRIC RESEARCHUL1RR024979 · NCRR · UNIVERSITY OF IOWA · PI ROSENTHAL, GARY E · 2007 to 2011
$31.8M
Fluoride & Other Factors in Childhood and Adolescent Bone DevelopmentR01DE012101 · NIDCR · UNIVERSITY OF IOWA · PI LEVY, STEVEN M. · 1998 to 2013
$11.9M
Fluoride, Dietary, and Other Factors Related to Young Adult Bone Measures and Dental CariesR56DE012101 · NIDCR · UNIVERSITY OF IOWA · PI LEVY, STEVEN M. · 2015 to 2017
$3.5M
Ultra-low Dose, High Speed, High Resolution, Multispectral, Multi-Source MDCT ScaS10OD018526 · OD · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED · 2015 to 2015
$2.0M
Tensor Scale-based Methods for Assessment of Trabecular Bone QualityR01AR054439 · NIAMS · UNIVERSITY OF IOWA · PI SAHA, PUNAM K. · 2009 to 2012
$1.4M
NCRR NIH HHS UL1 RR024979NIAMS NIH HHS R01 AR054439NIDCR NIH HHS R01 DE012101NIDCR NIH HHS R56 DE012101NIEHS NIH HHS P30 ES005605NIH HHS S10 OD018526
6 · The paper itself

Abstract

purposeOsteoporosis associated with reduced bone mineral density (BMD) and microarchitectural changes puts patients at an elevated risk of fracture. Modern multidetector row CT (MDCT) technology, producing high spatial resolution at increasingly lower dose radiation, is emerging as a viable modality for trabecular bone (Tb) imaging. Wide variation in CT scanners raises concerns of data uniformity in multisite and longitudinal studies. A comprehensive cadaveric study was performed to evaluate MDCT-derived Tb microarchitectural measures. A human pilot study was performed comparing continuity of Tb measures estimated from two MDCT scanners with significantly different image resolution features.

methodMicro-CT imaging of cadaveric ankle specimens (n=25) was used to examine the validity of MDCT-derived Tb microarchitectural measures. Repeat scan reproducibility of MDCT-based Tb measures and their ability to predict mechanical properties were examined. To assess multiscanner data continuity of Tb measures, the distal tibias of 20 volunteers (age:26.2±4.5Y,10F) were scanned using the Siemens SOMATOM Definition Flash and the higher resolution Siemens SOMATOM Force scanners with an average 45-day time gap between scans. The correlation of Tb measures derived from the two scanners over 30% and 60% peel regions at the 4% to 8% of distal tibia was analyzed.

resultsMDCT-based Tb measures characterizing bone network area density, plate-rod microarchitecture, and transverse trabeculae showed good correlations (r∈0.85,0.92) with the gold standard micro-CT-derived values of matching Tb measures. However, other MDCT-derived Tb measures characterizing trabecular thickness and separation, erosion index, and structure model index produced weak correlation (r<0.8) with their micro-CT-derived values. Most MDCT Tb measures were found repeatable (ICC∈0.94,0.98). The Tb plate-width measure showed a strong correlation (r = 0.89) with experimental yield stress, while the transverse trabecular measure produced the highest correlation (r = 0.81) with Young's modulus. The data continuity experiment showed that, despite significant differences in image resolution between two scanners (10% MTF along xy-plane and z-direction - Flash: 16.2 and 17.9 lp/cm; Force: 24.8 and 21.0 lp/cm), most Tb measures had high Pearson correlations (r > 0.95) between values estimated from the two scanners. Relatively lower correlation coefficients were observed for the bone network area density (r = 0.91) and Tb separation (r = 0.93) measures.

conclusionMost MDCT-derived Tb microarchitectural measures are reproducible and their values derived from two scanners strongly correlate with each other as well as with bone strength. This study has highlighted those MDCT-derived measures which show the greatest promise for characterization of bone network area density, plate-rod and transverse trabecular distributions with a good correlation (r ≥ 0.85) compared with their micro-CT-derived values. At the same time, other measures representing trabecular thickness and separation, erosion index, and structure model index produced weak correlations (r < 0.8) with their micro-CT-derived values, failing to accurately portray the projected trabecular microarchitectural features. Strong correlations of Tb measures estimated from two scanners suggest that image data from different scanners can be used successfully in multisite and longitudinal studies with linear calibration required for some measures. In summary, modern MDCT scanners are suitable for effective quantitative imaging of peripheral Tb microarchitecture if care is taken to focus on appropriate quantitative metrics.

Indexed as

AdultAgedAnkleBone and BonesFemaleHumansMaleReproducibility of ResultsX-Ray Microtomographybone mechanicsmicroarchitecturemodulation transfer functionmultidetector row CTtrabecular bone

Identifiers

PMID29064579
PMCPMC6345384
OpenAlexW2765968837

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.