Evidence map›Paper›PMID 29062267›Full record

ArticleFrontiers in neuroscience2017

Design and Preliminary Feasibility Study of a Soft Robotic Glove for Hand Function Assistance in Stroke Survivors.

Hong Kai Yap, Jeong Hoon Lim, Fatima Nasrallah, Chen-Hua Yeow

Erratum issued Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT04330417 (Bidirectional Myoelectric), which is not on this map. Cited by 42 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
42citing papers in PubMed, 1 pooled it
9.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04330417 nacompletednot on this mapstarted 2020, after this paper: background citation

Bidirectional Myoelectric (BIMYO) Soft Robotic Glove Technology For Robot-Assisted Hand Therapy in Stroke Patients

TypeinterventionalSponsorNational University Hospital, SingaporeRan2020 to 2021Enrolled6ConditionsStrokeArmsRobot-Assisted Hand Training, Standard Hand Therapy
3 · Its place in the literature

Who cites it

42 citing papers in PubMed, 1 synthesis or guideline pooled it, 186 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Hong Kai YapDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Jeong Hoon LimDepartment of Medicine, National University of Singapore, Singapore, Singapore.
Fatima NasrallahQueensland Brain Institute, University of Queensland, St. Lucia, QLD, Australia.
Chen-Hua YeowDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
National University of Singapore · SGUniversity of Queensland · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Various robotic exoskeletons have been proposed for hand function assistance during activities of daily living (ADL) of stroke survivors. However, traditional exoskeletons involve the use of complex rigid systems that impede the natural movement of joints, and thus reduce the wearability and cause discomfort to the user. The objective of this paper is to design and evaluate a soft robotic glove that is able to provide hand function assistance using fabric-reinforced soft pneumatic actuators. These actuators are made of silicone rubber which has an elastic modulus similar to human tissues. Thus, they are intrinsically soft and compliant. Upon air pressurization, they are able to support finger range of motion (ROM) and generate the desired actuation of the finger joints. In this work, the soft actuators were characterized in terms of their blocked tip force, normal and frictional grip force outputs. Combining the soft actuators and flexible textile materials, a soft robotic glove was developed for grasping assistance during ADL for stroke survivors. The glove was evaluated on five healthy participants for its assisted ROM and grip strength. Pilot test was performed in two stroke survivors to evaluate the efficacy of the glove in assisting functional grasping activities. Our results demonstrated that the actuators designed in this study could generate desired force output at a low air pressure. The glove had a high kinematic transparency and did not affect the active ROM of the finger joints when it was being worn by the participants. With the assistance of the glove, the participants were able to perform grasping actions with sufficient assisted ROM and grip strength, without any voluntary effort. Additionally, pilot test on stroke survivors demonstrated that the patient's grasping performance improved with the presence and assistance of the glove. Patient feedback questionnaires also showed high level of patient satisfaction and comfort. In conclusion, this paper has demonstrated the possibility of using soft wearable exoskeletons that are more wearable, lightweight, and suitable to be used on a daily basis for hand function assistance of stroke survivors during activities of daily living.

Indexed as

activities of daily livinghand exoskeletonrehabilitationsoft actuatorssoft robotic

Identifiers

PMID29062267
PMCPMC5640819
OpenAlexW2762463353

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.