Evidence map›Paper›PMID 29058079›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2018

Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall-Miles plate versus cables.

Gerard A Sheridan, Adam Galbraith, Stephen R Kearns, William Curtin, Colin G Murphy

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Gerard A Sheridan"Deerpark", Lobinstown, Navan, Co. Meath, Ireland. sheridga@tcd.ie.ORCID http://orcid.org/0000-0003-0970-3274
Adam GalbraithDepartment of Orthopaedic Surgery, University Hospital Galway, Newcastle Rd, Galway, Co. Galway, Ireland.
Stephen R KearnsDepartment of Orthopaedic Surgery, University Hospital Galway, Newcastle Rd, Galway, Co. Galway, Ireland.
William CurtinDepartment of Orthopaedic Surgery, University Hospital Galway, Newcastle Rd, Galway, Co. Galway, Ireland.
Colin G MurphyDepartment of Orthopaedic Surgery, University Hospital Galway, Newcastle Rd, Galway, Co. Galway, Ireland.
University Hospital Galway · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExtended trochanteric osteotomy (ETO) is a well-established surgical technique used for femoral stem retrieval in revision hip arthroplasty procedures. Fixation of ETO is commonly achieved through wire, cable or cable-plate fixation. No evidence exists to date to suggest which method is superior when used in an acute traumatic setting.

methodsThirty cases of acute periprosthetic fracture requiring femoral stem revision with an ETO were identified over a 10-year period. Each case had a loose femoral prosthesis which was revised using an ETO approach. Nineteen of these were fixed using cables only, and 11 were fixed using a cable-plate construct. Radiographic outcomes measured included greater trochanter migration, osteolysis, union, time to union and overall success using the Beals and Tower classification. Clinical outcomes were assessed using the modified Harris Hip Score.

resultsTwenty-three Vancouver B/C-type fractures were identified. The remaining seven consisted of other fracture types with a loose femoral stem requiring revision through ETO. Mean follow-up was 32 months in the cable group and 12 months in the cable-plate group. The cable-plate construct performed better than cables alone. Mean migration rates were 1.7 mm lower in the cable-plate group (p < 0.05). Beals and Tower classification of radiographic outcomes was significantly better in the cable-plate group (p < 0.01). Modified Harris Hip Scores were better in this group also (p < 0.05).

conclusionWhen utilising an ETO approach for femoral stem revision in acute periprosthetic fractures, superior clinical and radiographic outcomes can be achieved if fixation involves a cable-plate system instead of cables only.

Indexed as

Bone PlatesBone WiresAgedAged, 80 and overArthroplasty, Replacement, HipFemaleFracture HealingHip FracturesHumansMaleMiddle AgedOsteotomyPeriprosthetic FracturesRadiographyReoperationRetrospective StudiesCableCable–plateExtended trochanteric osteotomy (ETO)Periprosthetic fracture (PPF)

Identifiers

PMID29058079
OpenAlexW2765588509

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.