Evidence map›Paper›PMID 29058023›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial.

Vera Stetzelberger, Udo Obertacke, Ahmed Jawhar

Registry-linked trialAbstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02475603 (Clinical, Biochemical and Neurophysiological Consequences of Intraoperative), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02475603 naunknown statusnot on this map

Clinical, Biochemical and Neurophysiological Consequences of Intraoperative

TypeinterventionalSponsorUniversitätsmedizin MannheimRan2012 to 2016Enrolled100ConditionsMuscles IschemiaArmsTotal knee arthroplasty
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Vera StetzelbergerDepartment of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
Udo ObertackeDepartment of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
Ahmed JawharDepartment of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany. ahmed.jawhar@umm.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe accuracy of the identification of anatomical landmarks with versus without tourniquet application and its effect on implant positioning remained unknown. Therefore, the hypothesis of the present study was that tourniquet application did not affect the accuracy of the reconstruction of the mechanical leg alignment, the joint line level, and the patellar height.

methodsThe prospective randomized monocentric trial (Clinical-Trials.gov NCT02475603) included a total of 86 patients scheduled to undergo primary TKA. The patients were allocated to receive TKA with (Group A, n = 43) or without tourniquet (Group B, n = 43). The mechanical leg alignment, the joint line level (modified Kawamura), and the patellar height (Plateau-patella angle, Insall Salvati index, and modified Insall Salvati index) were measured pre- and postoperatively on standardized calibrated digital radiographs. Mean, SEM, median, range, and p value were calculated for each parameter.

resultsThere was no statistical difference between the groups with regard to demographics, preoperative deformity, implant design, and surgical technique (n.s.). The mechanical leg alignment, the joint line level, and the patellar height revealed, in both groups, similar results pre- and postoperatively (n.s.).

conclusionThe mechanical leg alignment, the joint line level, and the patellar height could be accurately reconstructed with and without tourniquet use. With respect to clinically relevant surrogate parameters of implant positioning, TKA can safely be performed without a tourniquet. Available data do not support a routine use of tourniquet during TKA and might justify a change of the clinical pathway. LEVEL OF EVIDENCE: Level I.