Evidence map›Paper›PMID 29057142›Full record

ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation

Design and Validation of a Torque Dense, Highly Backdrivable Powered Knee-Ankle Orthosis.

Hanqi Zhu, Jack Doan, Calvin Stence, Ge Lv, Toby Elery, Robert Gregg

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Design Principles for Compact, Backdrivable Actuation in Partial-Assist Powered Knee Orthoses.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2021
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Design and Validation of a Partial-Assist Knee Orthosis with Compact, Backdrivable Actuation.IEEE ... International Conference on Rehabilitation Robotics : [proceedings] · 2019
    Article
  8. Article
  9. Continuous-Phase Control of a Powered Knee-Ankle Prosthesis: Amputee Experiments Across Speeds and Inclines.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2018
    Article
  10. Design and Benchtop Validation of a Powered Knee-Ankle Prosthesis with High-Torque, Low-Impedance Actuators.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation · 2018
    Article
  11. Real-Time Continuous Gait Phase and Speed Estimation from a Single Sensor.Control Technology and Applications. Control Technology and Applications · 2017
    Article
  12. Towards Total Energy Shaping Control of Lower-Limb Exoskeletons.Proceedings of the ... American Control Conference. American Control Conference · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hanqi ZhuDepartment of Electrical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Jack DoanDepartment of Electrical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Calvin StenceDepartment of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Ge LvDepartment of Electrical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Toby EleryDepartment of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Robert GreggDepartment of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.

Funding

PHASE-BASED CONTROL OF LOCOMOTION FOR HIGH-PERFORMANCE PROSTHESES AND ORTHOSESDP2HD080349 · NICHD · UNIVERSITY OF TEXAS DALLAS · PI GREGG, ROBERT D · 2013 to 2013
$2.3M
NICHD NIH HHS DP2 HD080349
6 · The paper itself

Abstract

This paper presents the mechatronic design and experimental validation of a novel powered knee-ankle orthosis for testing torque-driven rehabilitation control strategies. The modular actuator of the orthosis is designed with a torque dense motor and a custom low-ratio transmission (24:1) to provide mechanical transparency to the user, allowing them to actively contribute to their joint kinematics during gait training. The 4.88 kg orthosis utilizes frameless components and light materials, such as aluminum alloy and carbon fiber, to reduce its mass. A human subject experiment demonstrates accurate torque control with high output torque during stance and low backdrive torque during swing at fast walking speeds. This work shows that backdrivability, precise torque control, high torque output, and light weight can be achieved in a powered orthosis without the high cost and complexity of variable transmissions, clutches, and/or series elastic components.

Identifiers

PMID29057142
PMCPMC5648365

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.