Evidence map›Paper›PMID 29050824›Full record

ArticleJournal of biomechanics2017

In vivo repeatability of the pulse wave inverse problem in human carotid arteries.

Matthew McGarry, Pierre Nauleau, Iason Apostolakis, Elisa Konofagou

Abstract read
In one paragraph

Article in Journal of biomechanics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matthew McGarryDepartment of Biomedical Engineering, Columbia University, New York, NY, United States; Thayer School of Engineering, Dartmouth College, Hanover, NH, United States.
Pierre NauleauDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Iason ApostolakisDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Elisa KonofagouDepartment of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Radiology, Columbia University, New York, NY, United States. Electronic address: ek2191@columbia.edu.

Funding

Carotid plaque assessment using Pulse Wave ImagingR01HL135734 · NHLBI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI KONOFAGOU, ELISA E. · 2017 to 2020
$2.5M
Noninvasive arrhythmia mapping using Electromechanical Wave ImagingR01HL114358 · NHLBI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI KONOFAGOU, ELISA E. · 2012 to 2016
$1.9M
NHLBI NIH HHS R01 HL114358NHLBI NIH HHS R01 HL135734
6 · The paper itself

Abstract

Accurate arterial stiffness measurement would improve diagnosis and monitoring for many diseases. Atherosclerotic plaques and aneurysms are expected to involve focal changes in vessel wall properties; therefore, a method to image the stiffness variation would be a valuable clinical tool. The pulse wave inverse problem (PWIP) fits unknown parameters from a computational model of arterial pulse wave propagation to ultrasound-based measurements of vessel wall displacements by minimizing the difference between the model and measured displacements. The PWIP has been validated in phantoms, and this study presents the first in vivo demonstration. The common carotid arteries of five healthy volunteers were imaged five times in a single session with repositioning of the probe and subject between each scan. The 1D finite difference computational model used in the PWIP spanned from the start of the transducer to the carotid bifurcation, where a resistance outlet boundary condition was applied to approximately model the downstream reflection of the pulse wave. Unknown parameters that were estimated by the PWIP included a 10-segment linear piecewise compliance distribution and 16 discrete cosine transformation coefficients for each of the inlet boundary conditions. Input data was selected to include pulse waves resulting from the primary pulse and dicrotic notch. The recovered compliance maps indicate that the compliance increases close to the bifurcation, and the variability of the average pulse wave velocity estimated through the PWIP is on the order of 11%, which is similar to that of the conventional processing technique which tracks the wavefront arrival time (13%).

Indexed as

Pulse Wave AnalysisAdultCarotid ArteriesComputer SimulationHealthy VolunteersHeart RateHumansMalePhantoms, ImagingPlaque, AtheroscleroticTransducersYoung AdultArteriesComplianceElastographyInverse problemsPulse wave imagingPulse wave velocity

Identifiers

PMID29050824
PMCPMC5694358

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.