Evidence map›Paper›PMID 29049235›Full record

Trial reportMedicine2017

Comparing the protective performances of 3 types of N95 filtering facepiece respirators during chest compressions: A randomized simulation study.

Hyungoo Shin, Jaehoon Oh, Tae Ho Lim, Hyunggoo Kang, Yeongtak Song, Sanghyun Lee

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. In-Hospital Cardiac Arrest.Emergency medicine clinics of North America · 2023
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Challenges, limitations, and solutions for orthodontists during the coronavirus pandemic: A review.American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2021
    Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hyungoo ShinDepartment of Emergency Medicine, College of Medicine Convergence Technology Center for Disaster Preparedness, Hanyang University Department of Emergency Medicine, College of Medicine, Hallym University, Seoul, Republic of Korea.
Jaehoon Oh
Tae Ho Lim
Hyunggoo Kang
Yeongtak Song
Sanghyun Lee

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveHealthcare providers in emergency departments should wear respirators for infection protection. However, the wearer's vigorous movements during cardiopulmonary resuscitation may affect the protective performance of the respirator. Herein, we aimed to assess the effects of chest compressions (CCs) on the protective performance of respirators.

methodsThis crossover study evaluated 30 healthcare providers from 1 emergency department who performed CC with real-time feedback. The first, second, and third groups started with a cup-type, fold-type, and valve-type respirator, respectively, after which the respirators were randomized for each group. The fit factors were measured using a quantitative fit testing device before and during the CC in each experiment. The protection rate was defined as the proportion of respirators achieving a fit factor ≥100.

resultsThe fold-type respirator had a significantly greater protection rate at baseline (100.0% ± 0.0%) compared to the cup-type (73.6% ± 39.6%, P = .003) and valve-type respirators (87.5% ± 30.3%, P = .012). During the CC, the fit factor values significantly decreased for the cup-type (44.9% ± 42.8%, P < .001) and valve-type respirators (59.5% ± 41.7%, P = .002), but not for the fold-type respirator (93.2% ± 21.7%, P = .095).

conclusionsThe protective performances of respirators may be influenced by CC. Healthcare providers should identify the respirator that provides the best fit for their intended tasks.

Indexed as

Equipment DesignHealth PersonnelRespiratory Protective DevicesAdultCardiopulmonary ResuscitationCross-Over StudiesFemaleHumansMaleMiddle AgedOccupational ExposureProspective StudiesYoung Adult

Identifiers

PMID29049235
PMCPMC5662401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.