Evidence map›Paper›PMID 29046919›Full record

ArticlePediatric radiology2018

Female gonadal shielding with automatic exposure control increases radiation risks.

Summer L Kaplan, Dennise Magill, Marc A Felice, Rui Xiao, Sayed Ali, Xiaowei Zhu

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. [The End of Patient Shielding: Rationale for Discontinuing the Practice].Journal of the Korean Society of Radiology · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Unified Open Hardware Platform for Digital X-Ray Devices; its Conceptual Model and First Implementation.IEEE journal of translational engineering in health and medicine · 2020
    Article
  13. Review
  14. Death of the ALARA Radiation Protection Principle as Used in the Medical Sector.Dose-response : a publication of International Hormesis Society
    Article
  15. Are Continued Efforts to Reduce Radiation Exposures from X-Rays Warranted?Dose-response : a publication of International Hormesis Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Summer L KaplanDepartment of Radiology, The Children's Hospital of Philadelphia, 34th Street & Civic Center Boulevard, Philadelphia, PA, 19104, USA. kaplans2@email.chop.edu.
Dennise MagillEnvironmental Health and Radiation Safety, University of Pennsylvania, Philadelphia, PA, USA.
Marc A FeliceEnvironmental Health and Radiation Safety, University of Pennsylvania, Philadelphia, PA, USA.
Rui XiaoDepartment of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA, USA.
Sayed AliDepartment of Radiology, Temple University Hospital, Philadelphia, PA, USA.
Xiaowei ZhuDepartment of Radiology, The Children's Hospital of Philadelphia, 34th Street & Civic Center Boulevard, Philadelphia, PA, 19104, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose to colon and stomach as well as to ovaries outside the shielded area.

objectiveWe assess changes in dose-area product (DAP) and absorbed organ dose when female gonadal shielding is used with AEC for pelvis radiography. MATERIALS AND

methodsWe imaged adult and 5-year-old equivalent dosimetry phantoms using pelvis radiograph technique with AEC in the presence and absence of a female gonadal shield. We recorded DAP and mAs and measured organ absorbed dose at six internal sites using film dosimetry.

resultsFemale gonadal shielding with AEC increased DAP 63% for the 5-year-old phantom and 147% for the adult phantom. Absorbed organ dose at unshielded locations of colon, stomach and ovaries increased 21-51% in the 5-year-old phantom and 17-100% in the adult phantom. Absorbed organ dose sampled under the shield decreased 67% in the 5-year-old phantom and 16% in the adult phantom.

conclusionFemale gonadal shielding combined with AEC during pelvic radiography increases absorbed dose to organs with greater radiation sensitivity and to unshielded ovaries. Difficulty in proper use of gonadal shields has been well described, and use of female gonadal shielding may be inadvisable given the risks of increasing radiation.