Evidence map›Paper›PMID 29043714›Full record

ArticleJournal of biomedical optics2017

Spectroscopic Doppler analysis for visible-light optical coherence tomography.

Xiao Shu, Wenzhong Liu, Lian Duan, Hao F Zhang

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Designing visible-light optical coherence tomography towards clinics.Quantitative imaging in medicine and surgery · 2019
    Article
  4. Visible-light optical coherence tomography: a review.Journal of biomedical optics · 2017
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Xiao ShuNorthwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States.
Wenzhong LiuOpticent Health, Evanston, Illinois, United States.
Lian DuanNorthwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States.
Hao F ZhangNorthwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States.
Northwestern University · US

Funding

Novel Antiangiogenic Peptides for Treatment of Exudative AMDR24EY022883 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI SHEIBANI, NADER · 2013 to 2017
$6.2M
Investigating oxygen metabolism in diabetic retinopathyR01EY026078 · NEI · NORTHWESTERN UNIVERSITY · PI SHEIBANI, NADER, ZHANG, HAO F · 2016 to 2020
$2.3M
Functional Retinal Imaging to Monitor Pharmaco-Therapies in Diabetic RetinopathyDP3DK108248 · NIDDK · NORTHWESTERN UNIVERSITY AT CHICAGO · PI FAWZI, AMANI A, ZHANG, HAO F · 2015 to 2015
$1.9M
A clinically applicable model of retinal oxygen metabolismR21EY027502 · NEI · NORTHWESTERN UNIVERSITY · PI LINSENMEIER, ROBERT A. · 2017 to 2018
$430k
NEI NIH HHS R01 EY026078NEI NIH HHS R21 EY027502NEI NIH HHS R24 EY022883NIDDK NIH HHS DP3 DK108248
6 · The paper itself

Abstract

Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.

Indexed as

Tomography, Optical CoherenceLightRetinaRetinal VesselsSpectrum Analysisoptical coherence tomographyoptical Doppler tomographyphase variationspectroscopic analysis

Identifiers

PMID29043714
PMCPMC5644441
OpenAlexW2765579845

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.