Evidence map›Paper›PMID 29043502›Full record

ArticleJournal of medical systems2017

An Integrated Approach Using Chaotic Map & Sample Value Difference Method for Electrocardiogram Steganography and OFDM Based Secured Patient Information Transmission.

Anukul Pandey, Barjinder Singh Saini, Butta Singh, Neetu Sood

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 30 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Anukul PandeyDepartment of Electronics and Communication Engineering, Dr B R Ambedkar National Institute of Technology, Jalandhar, PIN:144011, India. anukul66@gmail.com.ORCID http://orcid.org/0000-0003-2737-112X
Barjinder Singh SainiDepartment of Electronics and Communication Engineering, Dr B R Ambedkar National Institute of Technology, Jalandhar, PIN:144011, India.
Butta SinghDepartment of Electronics and Communication Engineering, Guru Nanak Dev University, Regional Campus, Jalandhar, PIN:144007, India.
Neetu SoodDepartment of Electronics and Communication Engineering, Dr B R Ambedkar National Institute of Technology, Jalandhar, PIN:144011, India.
Dr. B. R. Ambedkar National Institute of Technology Jalandhar · INGuru Nanak Dev University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a patient's confidential data hiding scheme in electrocardiogram (ECG) signal and its subsequent wireless transmission. Patient's confidential data is embedded in ECG (called stego-ECG) using chaotic map and the sample value difference approach. The sample value difference approach effectually hides the patient's confidential data in ECG sample pairs at the predefined locations. The chaotic map generates these predefined locations through the use of selective control parameters. Subsequently, the wireless transmission of the stego-ECG is analyzed using the Orthogonal Frequency Division Multiplexing (OFDM) system in a Rayleigh fading scenario for telemedicine applications. Evaluation of proposed method on all 48 records of MIT-BIH arrhythmia ECG database demonstrates that the embedding does not alter the diagnostic features of cover ECG. The secret data imperceptibility in stego-ECG is evident through the statistical and clinical performance measures. Statistical measures comprise of Percentage Root-mean-square Difference (PRD), Peak Signal to Noise Ratio (PSNR), and Kulback-Leibler Divergence (KL-Div), etc. while clinical metrics includes wavelet Energy Based Diagnostic Distortion (WEDD) and Wavelet based Weighted PRD (WWPRD). The various channel Signal-to-Noise Ratio scenarios are simulated for wireless communication of stego-ECG in OFDM system. The proposed method over all the 48 records of MIT-BIH arrhythmia database resulted in average, PRD = 0.26, PSNR = 55.49, KL-Div = 3.34 × 10

Indexed as

AlgorithmsSignal Processing, Computer-AssistedComputer SecurityConfidentialityElectrocardiographyHumansSignal-To-Noise RatioTelemetryChaotic mapData hidingECGECG steganographyOFDM systemPVDSample inversion

Identifiers

PMID29043502
OpenAlexW2765976091

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.