Evidence map›Paper›PMID 29041911›Full record

ArticleBMC anesthesiology2017

Role of tube size and intranasal compression of the nasotracheal tube in respiratory pressure loss during nasotracheal intubation: a laboratory study.

Koichi Futagawa, Yoshihiro Takasugi, Takeharu Kobayashi, Satoshi Morishita, Takahiko Okuda

Open access · goldAbstract read
In one paragraph

Article in BMC anesthesiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Koichi FutagawaDepartment of Anesthesiology, Nara Hospital, Kindai University Faculty of Medicine, 1248-1 Otodacho, Ikoma, Nara, 630-0293, Japan.
Yoshihiro TakasugiDepartment of Anesthesiology, Kindai University Faculty of Medicine, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan. dzc01654@nifty.com.ORCID http://orcid.org/0000-0001-8988-425X
Takeharu KobayashiProduct Development Research Center, Daiken Medical Co. Ltd., 2-6-2, Ayumino, Izumi-city, Osaka, 594-1157, Japan.
Satoshi MorishitaProduct Development Research Center, Daiken Medical Co. Ltd., 2-6-2, Ayumino, Izumi-city, Osaka, 594-1157, Japan.
Takahiko OkudaDepartment of Anesthesiology, Nara Hospital, Kindai University Faculty of Medicine, 1248-1 Otodacho, Ikoma, Nara, 630-0293, Japan.
Izumi City General Hospital · JPNara Medical University Hospital · JPKindai University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSmall nasotracheal tubes (NTTs) and intranasal compression of the NTT in the nasal cavity may contribute to increasing airway resistance. Since the effects of size, shape, and partial compression of the NTT on airway resistance have not been investigated, values of airway resistance with partial compression of preformed NTTs of various sizes were determined.

methodsTo determine the factors affecting the respiratory pressure loss during the nasotracheal intubation, physical and fluid dynamics simulations were used. The internal minor axes of NTTs in the nasal cavity of intubated patients were measured using dial calipers. In physical and fluid dynamics simulations, pressure losses through the tubular parts, compressed parts, and slip joints of NTTs with internal diameters (IDs) of 6.0, 6.5, 7.0, 7.5, and 8.0 mm were estimated under partial compression.

resultsThe median internal minor axes of the 7.0- and 7.5-mm ID NTTs in the nasal cavity were 5.2 (4.3-5.6) mm and 6.0 (4.2-7.0) mm, respectively. With a volumetric air flow rate of 30 L/min, pressure losses through uncompressed NTTs with IDs of 6.0-, 6.5-, 7.0-, 7.5- and 8.0-mm were 651.6 ± 5.7 (6.64 ± 0.06), 453.4 ± 3.9 (4.62 ± 0.04), 336.5 ± 2.2 (3.43 ± 0.02), 225.2 ± 0.2 (2.30 ± 0.00), and 179.0 ± 1.1 Pa (1.82 ± 0.01 cmH

conclusionPressure losses through NTTs are in inverse proportion to the tubes' IDs; greater pressure losses due to slip joints, acute bending, and partial compression of the NTT were obvious in small NTTs. Pressure losses through NTTs, especially in small NTTs, could increase the work of breathing to a greater extent than that through standard tubes; intranasal compression further increases the pressure loss.

Indexed as

Compressive StrengthAdministration, IntranasalAdolescentAdultAgedAged, 80 and overAirway ResistanceFemaleHumansIntubation, IntratrachealMaleMaximal Respiratory PressuresMiddle AgedNasal CavityRespiratory MechanicsYoung AdultEndotracheal tubeNasotracheal intubationPressure lossSlip jointTurbulent flow

Identifiers

PMID29041911
PMCPMC5645985
OpenAlexW2765843138

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.