Evidence map›Paper›PMID 29034168›Full record

ArticlePhotoacoustics2017

Quantitative comparison of PZT and CMUT probes for photoacoustic imaging: Experimental validation.

Maëva Vallet, François Varray, Jérôme Boutet, Jean-Marc Dinten, Giosuè Caliano, Alessandro Stuart Savoia, Didier Vray

Open access · goldAbstract read
In one paragraph

Article in Photoacoustics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
3.3field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 62 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Optical ultrasound sensors for photoacoustic imaging: a narrative review.Quantitative imaging in medicine and surgery · 2022
    Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Maëva ValletUniv Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Lyon, France.
François VarrayUniv Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Lyon, France.
Jérôme BoutetCEA-LETI, MINATEC, F-38054 Grenoble, France.
Jean-Marc DintenCEA-LETI, MINATEC, F-38054 Grenoble, France.
Giosuè CalianoDipartimento di Ingegneria, Università degli Studi Roma Tre, Rome, Italy.
Alessandro Stuart SavoiaDipartimento di Ingegneria, Università degli Studi Roma Tre, Rome, Italy.
Didier VrayUniv Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Lyon, France.
Université Claude Bernard Lyon 1 · FRInstitut polytechnique de Grenoble · FRRoma Tre University · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photoacoustic (PA) signals are short ultrasound (US) pulses typically characterized by a single-cycle shape, often referred to as N-shape. The spectral content of such wideband signals ranges from a few hundred kilohertz to several tens of megahertz. Typical reception frequency responses of classical piezoelectric US imaging transducers, based on PZT technology, are not sufficiently broadband to fully preserve the entire information contained in PA signals, which are then filtered, thus limiting PA imaging performance. Capacitive micromachined ultrasonic transducers (CMUT) are rapidly emerging as a valid alternative to conventional PZT transducers in several medical ultrasound imaging applications. As compared to PZT transducers, CMUTs exhibit both higher sensitivity and significantly broader frequency response in reception, making their use attractive in PA imaging applications. This paper explores the advantages of the CMUT larger bandwidth in PA imaging by carrying out an experimental comparative study using various CMUT and PZT probes from different research laboratories and manufacturers. PA acquisitions are performed on a suture wire and on several home-made bimodal phantoms with both PZT and CMUT probes. Three criteria, based on the evaluation of pure receive impulse response, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) respectively, have been used for a quantitative comparison of imaging results. The measured fractional bandwidths of the CMUT arrays are larger compared to PZT probes. Moreover, both SNR and CNR are enhanced by at least 6 dB with CMUT technology. This work highlights the potential of CMUT technology for PA imaging through qualitative and quantitative parameters.

Indexed as

CMUTPhotoacousticPZTUltrasound imaging

Identifiers

PMID29034168
PMCPMC5635341
OpenAlexW2760078659

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.