ArticleJournal of medical devices2017

Effects of Sterilization on Shape Memory Polyurethane Embolic Foam Devices.

Rachael Muschalek, Landon Nash, Ryan Jones, Sayyeda M Hasan, Brandis K Keller, Mary Beth B Monroe, Duncan J Maitland

Abstract read
In one paragraph

Article in Journal of medical devices, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Development of Biopsy Tract Sealants Based on Shape Memory Polymer Foams.Biomedical materials & devices (New York, N.Y.) · 2023
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rachael MuschalekBiomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail: rmuschalek2015@gmail.com.
Landon NashBiomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail: nashlandon@gmail.com.
Ryan JonesBiomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail: jonesrya@tamu.edu.
Sayyeda M HasanBiomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail: marziyahasan@gmail.com.
Brandis K KellerBiomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail: bkeller@tamu.edu.
Mary Beth B MonroeBiomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail: mbbmonroe@tamu.edu.
Duncan J MaitlandBiomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail: djmaitland@tamu.edu.

Funding

Shape Memory Polymer Embolic Foams for Treating Cerebrovascular AneurysmsU01NS089692 · NINDS · TEXAS ENGINEERING EXPERIMENT STATION · PI MAITLAND, DUNCAN J · 2015 to 2018
$2.5M
NINDS NIH HHS U01 NS089692
6 · The paper itself

Abstract

Polyurethane shape memory polymer (SMP) foams have been developed for various embolic medical devices due to their unique properties in minimally invasive biomedical applications. These polyurethane materials can be stored in a secondary shape, from which they can recover their primary shape after exposure to an external stimulus, such as heat and water exposure. Tailored actuation temperatures of SMPs provide benefits for minimally invasive biomedical applications, but incur significant challenges for SMP-based medical device sterilization. Most sterilization methods require high temperatures or high humidity to effectively reduce the bioburden of the device, but the environment must be tightly controlled after device fabrication. Here, two probable sterilization methods (nontraditional ethylene oxide (ntEtO) gas sterilization and electron beam irradiation) are investigated for SMP medical devices. Thermal characterization of the sterilized foams indicated that ntEtO gas sterilization significantly decreased the glass transition temperature. Further material characterization was undertaken on the electron beam (ebeam) sterilized samples, which indicated minimal changes to the thermomechanical integrity of the bulk foam and to the device functionality.

Identifiers

PMID29034056