ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2017
A pulse programmable parahydrogen polarizer using a tunable electromagnet and dual channel NMR spectrometer.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- High-resolution microtesla in-situJournal of magnetic resonance (San Diego, Calif. : 1997) · 2026Article
- Rapid in situ carbon-13 hyperpolarization and imaging of acetate and pyruvate esters without external polarizer.Communications chemistry · 2024Article
- Low-Cost Purpose-Built Ultra-Low-Field NMR Spectrometer.Analytical chemistry · 2024Article
- MATRESHCA: Microtesla Apparatus for Transfer of Resonance Enhancement of Spin Hyperpolarization via Chemical Exchange and Addition.Analytical chemistry · 2024Article
- Quasi-continuous production of highly hyperpolarized carbon-13 contrast agents every 15 seconds within an MRI system.Communications chemistry · 2022Article
- Order-UnityChemphyschem : a European journal of chemical physics and physical chemistry · 2022Article
- Instrumentation for Hydrogenative Parahydrogen-Based Hyperpolarization Techniques.Analytical chemistry · 2022Article
- PHIP hyperpolarized [1-Scientific reports · 2021Article
- Parahydrogen-Induced Radio Amplification by Stimulated Emission of Radiation.Angewandte Chemie (International ed. in English) · 2020Article
- Pulse-Programmable Magnetic Field Sweeping of Parahydrogen-Induced Polarization by Side Arm Hydrogenation.Analytical chemistry · 2020Article
- In Situ SABRE Hyperpolarization with Earth's Field NMR Detection.Molecules (Basel, Switzerland) · 2019Article
- Hyperpolarizing Concentrated MetronidazoleChemistry (Weinheim an der Bergstrasse, Germany) · 2019Article
- Relaxation Dynamics of Nuclear Long-Lived Spin States in Propane and Propane-dThe journal of physical chemistry. C, Nanomaterials and interfaces · 2019Article
- Metabolic and Molecular Imaging with Hyperpolarised Tracers.Molecular imaging and biology · 2018Review
- Effects of Deuteration ofThe journal of physical chemistry. C, Nanomaterials and interfaces · 2018Article
- Quasi-Resonance Signal Amplification by Reversible Exchange.The journal of physical chemistry letters · 2018Article
- Parahydrogen-Based Hyperpolarization for Biomedicine.Angewandte Chemie (International ed. in English) · 2018Review
- SABRE hyperpolarization enables high-sensitivityThe Analyst · 2018Article
- Synthesis of Unsaturated Precursors for Parahydrogen-Induced Polarization and Molecular Imaging of 1-ACS omega · 2018Article
- Hyperpolarized NMR Spectroscopy: d-DNP, PHIP, and SABRE Techniques.Chemistry, an Asian journal · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Applications of parahydrogen induced polarization (PHIP) often warrant conversion of the chemically-synthesized singlet-state spin order into net heteronuclear magnetization. In order to obtain optimal yields from the overall hyperpolarization process, catalytic hydrogenation must be tightly synchronized to subsequent radiofrequency (RF) transformations of spin order. Commercial NMR consoles are designed to synchronize applied waves on multiple channels and consequently are well-suited as controllers for these types of hyperpolarization experiments that require tight coordination of RF and non-RF events. Described here is a PHIP instrument interfaced to a portable NMR console operating with a static field electromagnet in the milliTesla regime. In addition to providing comprehensive control over chemistry and RF events, this setup condenses the PHIP protocol into a pulse-program that in turn can be readily shared in the manner of traditional pulse sequences. In this device, a TTL multiplexer was constructed to convert spectrometer TTL outputs into 24 VDC signals. These signals then activated solenoid valves to control chemical shuttling and reactivity in PHIP experiments. Consolidating these steps in a pulse-programming environment speeded calibration and improved quality assurance by enabling the B
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.