Evidence map›Paper›PMID 29025728›Full record

ArticleAJNR. American journal of neuroradiology2017

Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT.

O Nikoubashman, A Nikoubashman, M Büsen, M Wiesmann

Open access · hybridAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed, 1 synthesis or guideline pooled it, 65 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Mechanical thrombectomy with a new intermediate balloon catheter combining the BGC and DAC features: Initial clinical experience with the iNedit device.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  6. Article
  7. An in vitro assessment of aspiration technologies: Location of conduit for 6F aspiration catheters and design of catheter tip influence clot retrieval success.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  8. Article
  9. Article
  10. Self-Steering Catheters for Neuroendovascular Interventions.IEEE transactions on medical robotics and bionics · 2024
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

O NikoubashmanFrom the Department of Diagnostic and Interventional Neuroradiology (O.N., M.W.), University Hospital, RWTH Aachen University, Aachen, Germany onikoubashman@ukaachen.de.ORCID http://orcid.org/0000-0002-2055-4217
A NikoubashmanInstitute of Physics (A.N.), Johannes Gutenberg University Mainz, Mainz, Germany.ORCID http://orcid.org/0000-0003-0563-825X
M BüsenInstitute of Applied Medical Engineering (M.B.), RWTH Aachen University, Aachen, Germany.ORCID http://orcid.org/0000-0001-9758-2892
M WiesmannFrom the Department of Diagnostic and Interventional Neuroradiology (O.N., M.W.), University Hospital, RWTH Aachen University, Aachen, Germany.ORCID http://orcid.org/0000-0002-8261-5513
Universitätsklinikum Aachen · DEJohannes Gutenberg University Mainz · DERWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeLarge-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND

methodsWe established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration catheter and aspiration with a 60-mL syringe versus an aspiration pump.

resultsAccording to our calculations, catheters with an inner diameter of >0.040 inch and >0.064 inch, respectively, are needed to be effective in the middle cerebral artery (2.5-mm diameter) or in the internal carotid artery (4 mm) in an average patient. There was a significant correlation between predicted and actual thrombectomy results (

conclusionsOur theoretic model allows estimating the minimal catheter diameters needed for successful mechanical thrombectomy with ADAPT, as demonstrated by the good agreement with our animal experiments. Our model will be helpful to interventionalists in avoiding selecting catheters that are likely too small to be effective.

Indexed as

CathetersAnimalsMechanical ThrombolysisStrokeSwineTreatment Outcome

Identifiers

PMID29025728
PMCPMC7963740
OpenAlexW2761465452

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.