Trial reportBMJ open2017
Hypothermic oxygenated machine perfusion (HOPE) for orthotopic liver transplantation of human liver allografts from extended criteria donors (ECD) in donation after brain death (DBD): a prospective multicentre randomised controlled trial (HOPE ECD-DBD).
Trial report in BMJ open, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 42 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Hypothermic Oxygenated Machine Perfusion (HOPE) for Liver Transplantation of Human Liver Allografts From Extended Criteria Donors (ECD) in Donation After Brain Death (DBD); a Multicenter Randomized Controlled Trial (HOPE ECD-DBD)
Hypothermic Oxygenated Perfusion To Reduce Tumour Recurrence After Liver Transplantation In Patients With Hepatocarcinoma
Who cites it
42 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Machine perfusion of the liver and in vivo animal models: A systematic review of the preclinical research landscape.PloS one · 2024Pooled it
- Machine perfusion in liver transplantation.The Cochrane database of systematic reviews · 2023Pooled it
- Improved outcomes after hypothermic oxygenated machine perfusion in liver transplantation-Long-term follow-up of a multicenter randomized controlled trial.Hepatology communications · 2024Trial
- Trial
- Decrease of renal resistance during hypothermic oxygenated machine perfusion is associated with early allograft function in extended criteria donation kidney transplantation.Scientific reports · 2020Trial
- Machine Perfusion in Liver Transplantation: A Systematic Review and Meta-Analysis Comparing Outcomes with Conventional Static Cold Storage.Journal of clinical medicine · 2026Review
- Effects of hypothermic oxygenated machine perfusion on bile composition after liver transplantation - Findings from a randomized controlled trial.JHEP reports : innovation in hepatology · 2026Article
- Liver Machine Perfusion: Past, Present and Future Directions.Biomedicines · 2025Review
- Protective value of ischemia-free liver transplantation on post-transplant acute kidney injury.JHEP reports : innovation in hepatology · 2025Article
- Successful Transplantation of a Liver from a Donor with HELLP Syndrome Undergoing Hypothermic Oxygenated Machine Perfusion (HOPE) Prior to Implantation.The American journal of case reports · 2023Article
- Liver Transplantation for Hepatic Metastases from Colorectal Cancer: Current Knowledge and Open Issues.Cancers · 2023Review
- Hypothermic Oxygenated Machine Perfusion (HOPE) Prior to Liver Transplantation Mitigates Post-Reperfusion Syndrome and Perioperative Electrolyte Shifts.Journal of clinical medicine · 2022Article
- Liver Machine Perfusion-When Physiopathology Matters.Journal of clinical medicine · 2022Article
- Metabolomics and integrated network pharmacology analysis reveal SNKAF decoction suppresses cell proliferation and induced cell apoptisis in hepatocellular carcinoma via PI3K/Akt/P53/FoxO signaling axis.Chinese medicine · 2022Article
- New Frontiers in Organ Preservation and Hepatoprotection.International journal of molecular sciences · 2022Article
- Prolonged dual hypothermic oxygenated machine preservation (DHOPE-PRO) in liver transplantation: study protocol for a stage 2, prospective, dual-arm, safety and feasibility clinical trial.BMJ open gastroenterology · 2022Article
- Dual Versus Single Oxygenated Hypothermic Machine Perfusion of Porcine Livers: Impact on Hepatobiliary and Endothelial Cell Injury.Transplantation direct · 2021Article
- Various myosteatosis selection criteria and their value in the assessment of short- and long-term outcomes following liver transplantation.Scientific reports · 2021Article
- Intraoperative Transfusion of Fresh Frozen Plasma Predicts Morbidity Following Partial Liver Resection for Hepatocellular Carcinoma.Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract · 2021Article
- The role of recipient myosteatosis in graft and patient survival after deceased donor liver transplantation.Journal of cachexia, sarcopenia and muscle · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionOrthotopic liver transplantation (OLT) has emerged as the mainstay of treatment for end-stage liver disease. In an attempt to improve the availability of donor allografts and reduce waiting list mortality, graft acceptance criteria were extended increasingly over the decades. The use of extended criteria donor (ECD) allografts is associated with a higher incidence of primary graft non-function and/or delayed graft function. As such, several strategies have been developed aiming at reconditioning poor quality ECD liver allografts. Hypothermic oxygenated machine perfusion (HOPE) has been successfully tested in preclinical experiments and in few clinical series of donation after cardiac death OLT. METHODS AND ANALYSIS: HOPE ECD-DBD is an investigator-initiated, open-label, phase-II, prospective multicentre randomised controlled trial on the effects of HOPE on ECD allografts in donation after brain death (DBD) OLT. Human whole organ liver grafts will be submitted to 1-2 hours of HOPE (n=23) via the portal vein before implantation and are going to be compared with a control group (n=23) of patients transplanted after conventional cold storage. Primary (peak and Δ peak alanine aminotransferase within 7 days) and secondary (aspartate aminotransferase, bilirubin and international normalised ratio, postoperative complications, early allograft dysfunction, duration of hospital and intensive care unit stay, 1-year patient and graft survival) endpoints will be analysed within a 12-month follow-up. Extent of ischaemia-reperfusion (I/R) injury will be assessed using liver tissue, perfusate, bile and serum samples taken during the perioperative phase of OLT. ETHICS AND DISSEMINATION: The study was approved by the institutional review board of the RWTH Aachen University, Aachen, Germany (EK 049/17). The current paper represent the pre-results phase. First results are expected in 2018. TRIAL REGISTRATION NUMBER: NCT03124641.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.