Evidence map›Paper›PMID 28994668›Full record

ArticlePhysics in medicine and biology2017

Correction of patient motion in cone-beam CT using 3D-2D registration.

S Ouadah, M Jacobson, J W Stayman, T Ehtiati, C Weiss, J H Siewerdsen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Joint Cone-Beam CT Reconstruction and Rigid Motion Compensation Using A Differentiable Projector.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  5. Article
  6. Article
  7. Head CT Scan Motion Artifact Correction via Diffusion-Based Generative Models.Applications of medical artificial intelligence : third international workshop, AMAI 2024, held in conjunction with MICCAI 2024, Marrakesh, Morocco, October 6, 2024 : proceedings. AMAI (Workshop) (3rd : 2024 : Marrakech, Morocco) · 2025
    Article
  8. Article
  9. Portable head CT motion artifact correction via diffusion-based generative model.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2025
    Article
  10. Article
  11. Optimizing Conditional DDPM for Head CT Motion Artifact Reduction: Brain vs. Skull and 3D vs. 2D.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024
    Article
  12. [A deep blur learning-based motion artifact reduction algorithm for dental cone-beam computed tomography images].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2024
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. [Four-dimensional cone-beam CT reconstruction based on motion-compensated robust principal component analysis].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2021
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

S OuadahDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, United States of America.
M JacobsonDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, United States of America.
J W StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, United States of America.
T EhtiatiSiemens Medical Solutions USA, Inc., Imaging and Therapy Systems, Hoffman Estates IL 60192, United States of America.
C WeissDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, United States of America.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD 21205, United States of America.

Funding

Intraoperative Imaging for Guidance, Patient Safety, and OR Quality AssuranceR01EB017226 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SIEWERDSEN, JEFFREY H · 2014 to 2017
$2.1M
NIBIB NIH HHS R01 EB017226
6 · The paper itself

Abstract

Cone-beam CT (CBCT) is increasingly common in guidance of interventional procedures, but can be subject to artifacts arising from patient motion during fairly long (~5-60 s) scan times. We present a fiducial-free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in the intrinsic and extrinsic parameters of geometric calibration. The 3D-2D registration process registers each projection to a prior 3D image by maximizing gradient orientation using the covariance matrix adaptation-evolution strategy optimizer. The resulting rigid transforms are applied to the system projection matrices, and a 3D image is reconstructed via model-based iterative reconstruction. Phantom experiments were conducted using a Zeego robotic C-arm to image a head phantom undergoing 5-15 cm translations and 5-15° rotations. To further test the algorithm, clinical images were acquired with a CBCT head scanner in which long scan times were susceptible to significant patient motion. CBCT images were reconstructed using a penalized likelihood objective function. For phantom studies the structural similarity (SSIM) between motion-free and motion-corrected images was  >0.995, with significant improvement (p  <  0.001) compared to the SSIM values of uncorrected images. Additionally, motion-corrected images exhibited a point-spread function with full-width at half maximum comparable to that of the motion-free reference image. Qualitative comparison of the motion-corrupted and motion-corrected clinical images demonstrated a significant improvement in image quality after motion correction. This indicates that the 3D-2D registration method could provide a useful approach to motion artifact correction under assumptions of local rigidity, as in the head, pelvis, and extremities. The method is highly parallelizable, and the automatic correction of residual geometric calibration errors provides added benefit that could be valuable in routine use.

Indexed as

Cone-Beam Computed TomographyMovementAlgorithmsArtifactsCalibrationHumansImaging, Three-DimensionalPhantoms, Imaging

Identifiers

PMID28994668
PMCPMC5894892

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.