Evidence map›Paper›PMID 28988288›Full record

ArticleDysphagia2018

Effects of Mechanical Complications on Radiation Exposure During Fluoroscopically Guided Gastrojejunostomy Exchange in the Pediatric Population.

Kevin S H Koo, Joseph Reis, Jodi Manchester, Gulraiz Chaudry, Brian Dillon

Abstract read
PubMed Publisher
In one paragraph

Article in Dysphagia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Kevin S H KooDepartment of Radiology, Seattle Children's Hospital, 4800 Sand Point Way NE, Seattle, WA, 98105, USA. kevin.koo@seattlechildrens.org.
Joseph ReisDepartment of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA.
Jodi ManchesterDepartment of Radiology, Boston Children's Hospital, Boston, MA, USA.
Gulraiz ChaudryDepartment of Radiology, Boston Children's Hospital, Boston, MA, USA.
Brian DillonDepartment of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA.
Boston Children's Hospital · USSeattle Children's Hospital · USUniversity of Rochester Medical Center · USYale University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of the article is to evaluate the effects of mechanical complications, such as clogging or coiling, of gastrojejunostomy tubes on radiation exposure during exchange in the pediatric population. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed procedural records for patients undergoing gastrojejunostomy (GJ) tube exchange during a 4-month period in 2014. Success of the procedure, specifications of the tube, age, and sex of the patient as well as radiation exposure during the procedure were included. Radiation exposure was measured in fluoroscopy time and cumulative air kerma. Complications encountered during exchange were also recorded, if available. Patients presenting for gastrostomy to GJ conversions or combined procedures were excluded from the study. Ordinary and mixed effect linear regression models were used to test associations between GJ tube parameters, presence of mechanical complications, and fluoroscopy time and radiation dose. 146 patients undergoing 285 GJ exchanges met inclusion criteria over the 4-month study period (M:F 82:64). All exchanges were successful with 85 demonstrating a form of mechanical complication (44 coiled, 41 clogged). Of the reported GJ tube specifications, only tube length was significantly associated with mechanical complications (p < 0.001). The presence of mechanical complication was significantly associated with increased radiation exposure and fluoroscopy time (p < 0.0001). Mechanical complications of gastrojejunostomy tubes, such as clogging or coiling, are associated with increased radiation exposure during exchange. Strategies to decrease these complications, including re-siting the gastrostomy tract or placement of a surgical jejunostomy in the event of repeated coiling of a tube should be strongly considered.

Indexed as

Equipment FailureGastrostomyJejunostomyRadiation ExposureChildEnteral NutritionFluoroscopyGastric BypassHumansPatient SafetyRetrospective StudiesCloggingCoilingComplicationsDeglutitionDeglutition disordersGastrojejunostomy tubesPediatricsRadiation

Identifiers

PMID28988288
OpenAlexW2761359604

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.