ReviewNeurophotonics2018
Review of recent progress toward a fiberless, whole-scalp diffuse optical tomography system.
Review in Neurophotonics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 62 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
62 citing papers in PubMed.
- CW-fDOT with a standard optical brain model: improving hemodynamic sensitivity and functional localization.Neurophotonics · 2026Article
- Advances in fully integrated wearable near-infrared spectroscopy: hardware innovations and biomedical applications.JPhys photonics · 2026Review
- Listening to a Consonant Chord Progression during Live Face-to-Face Gaze Enhances Neural Activity in Social Systems.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2026Article
- Quantifying the impact of hair and skin characteristics on fNIRS signal quality for enhanced inclusivity.Nature human behaviour · 2025Article
- High-density multidistance fNIRS enhances detection of brain activity during a word-color Stroop task.Neurophotonics · 2025Article
- Reconfigurable hardware-accelerated, multi-channel, adaptive temperature control platform of VCSELs for high-density fNIRS/DOT.Biomedical optics express · 2025Article
- Continuous Wave-Diffuse Optical Tomography (CW-DOT) in Human Brain Mapping: A Review.Sensors (Basel, Switzerland) · 2025Review
- A Deep-Learning Empowered, Real-Time Processing Platform of fNIRS/DOT for Brain Computer Interfaces and Neurofeedback.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2025Article
- Multimodal fNIRS-EEG sensor fusion: Review of data-driven methods and perspective for naturalistic brain imaging.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Simultaneous Mental Fatigue and Mental Workload Assessment With Wearable High-Density Diffuse Optical Tomography.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2025Article
- A bimodal deep learning network based on CNN for fine motor imagery.Cognitive neurodynamics · 2024Article
- Quantifying the Impact of Hair and Skin Characteristics on Signal Quality with Practical Recommendations for Improvement.bioRxiv : the preprint server for biology · 2024Article
- ninjaNIRS: an open hardware solution for wearable whole-head high-density functional near-infrared spectroscopy.Biomedical optics express · 2024Article
- Customizable optode attachments to improve hair clearance timing and inclusiveness in functional near-infrared spectroscopy research.Neurophotonics · 2024Article
- Flexible circuit-based spatially aware modular optical brain imaging system for high-density measurements in natural settings.Neurophotonics · 2024Article
- Flexible-circuit-based 3-D aware modular optical brain imaging system for high-density measurements in natural settings.medRxiv : the preprint server for health sciences · 2024Article
- Mapping brain function in adults and young children during naturalistic viewing with high-density diffuse optical tomography.Human brain mapping · 2024Article
- Pre-hospital stroke monitoring past, present, and future: a perspective.Frontiers in neurology · 2024Article
- fNIRS-EEG BCIs for Motor Rehabilitation: A Review.Bioengineering (Basel, Switzerland) · 2023Review
- Anatomical Modeling and Optimization of Speckle Contrast Optical Tomography.bioRxiv : the preprint server for biology · 2023Article
2 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The development of a whole-scalp, high sampling-density diffuse optical tomography (DOT) system is a critical next step in the evolution of the field of diffuse optics. To achieve this with optical fiber bundles is extremely challenging, simply because of the sheer number of bundles required, and the associated challenges of weight and ergonomics. Dispensing with optical fiber bundles and moving to head-mounted optoelectronics can potentially facilitate the advent of a new generation of wearable, whole-scalp technologies that will open up a range of new experimental and clinical applications for diffuse optical measurements. Here, we present a concise review of the significant progress that has been made toward achieving a wearable, fiberless, high-density, whole-scalp DOT system. We identify the key limitations of current technologies and discuss the possible opportunities for future development.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials