Evidence map›Paper›PMID 28982295›Full record

ArticleThe Libyan journal of medicine2017

Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD.

Yasin Hamarat, Mantas Deimantavicius, Evaldas Kalvaitis, Lina Siaudvytyte, Ingrida Januleviciene, Rolandas Zakelis, Laimonas Bartusis

Open access · goldAbstract readValidation Study
In one paragraph

Article in The Libyan journal of medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Non-invasive detection of intracranial pressure related to the optic nerve.Quantitative imaging in medicine and surgery · 2021
    Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Yasin Hamarata Health Telematics Science Institute , Kaunas University of Technology , Kaunas , Lithuania.ORCID http://orcid.org/0000-0002-1343-5068
Mantas Deimantaviciusa Health Telematics Science Institute , Kaunas University of Technology , Kaunas , Lithuania.
Evaldas Kalvaitisa Health Telematics Science Institute , Kaunas University of Technology , Kaunas , Lithuania.
Lina Siaudvytyteb Eye Clinic , Lithuanian University of Health Sciences , Kaunas , Lithuania.
Ingrida Janulevicieneb Eye Clinic , Lithuanian University of Health Sciences , Kaunas , Lithuania.
Rolandas Zakelisa Health Telematics Science Institute , Kaunas University of Technology , Kaunas , Lithuania.
Laimonas Bartusisa Health Telematics Science Institute , Kaunas University of Technology , Kaunas , Lithuania.ORCID http://orcid.org/0000-0001-5835-5697
Kaunas University of Technology · LTHospital of Lithuanian University of Health Sciences Kaunas Clinics · LT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. ABBREVIATIONS: OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.

Indexed as

Intracranial PressureAdultCarotid Artery, InternalCase-Control StudiesDiagnostic Techniques, OphthalmologicalFemaleGlaucomaHumansMaleOphthalmic ArteryProspective StudiesReproducibility of ResultsUltrasonography, Doppler, Transcranialinternal carotid arteryintracranial pressurelocation of the ophthalmic arterynon-invasive measurementUltrasonic Doppler technology

Identifiers

PMID28982295
PMCPMC7182302
OpenAlexW2761699810

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked