Evidence map›Paper›PMID 28981411›Full record

ArticleIEEE transactions on medical imaging2017

Z-Index Parameterization for Volumetric CT Image Reconstruction via 3-D Dictionary Learning.

Ti Bai, Hao Yan, Xun Jia, Steve Jiang, Ge Wang, Xuanqin Mou

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ti Bai
Hao Yan
Xun Jia
Steve Jiang
Ge Wang
Xuanqin Mou

Funding

High dose efficiency CT SystemU01EB017140 · NIBIB · STANFORD UNIVERSITY · PI EDIC, PETER, PELC, NORBERT J. · 2014 to 2018
$5.4M
Low dose cone beam CT for image guided adaptive radiotherapyR01CA154747 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI JIANG, STEVE BIN · 2011 to 2015
$1.4M
Grating-based X-ray Phase-contrast Tomography MethodsR01EB016977 · NIBIB · RENSSELAER POLYTECHNIC INSTITUTE · PI WANG, GE · 2014 to 2017
$1.3M
4D cone beam CT reconstruction for radiotherapy via motion vector optimizationR21EB017978 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI JIA, XUN · 2014 to 2015
$444k
A progressive cone-beam CT dose control scheme for image-guided radiation therapyR21CA178787 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI JIA, XUN · 2014 to 2015
$380k
NCI NIH HHS R01 CA154747NCI NIH HHS R21 CA178787NIBIB NIH HHS R01 EB016977NIBIB NIH HHS R21 EB017978NIBIB NIH HHS U01 EB017140
6 · The paper itself

Abstract

Despite the rapid developments of X-ray cone-beam CT (CBCT), image noise still remains a major issue for the low dose CBCT. To suppress the noise effectively while retain the structures well for low dose CBCT image, in this paper, a sparse constraint based on the 3-D dictionary is incorporated into a regularized iterative reconstruction framework, defining the 3-D dictionary learning (3-DDL) method. In addition, by analyzing the sparsity level curve associated with different regularization parameters, a new adaptive parameter selection strategy is proposed to facilitate our 3-DDL method. To justify the proposed method, we first analyze the distributions of the representation coefficients associated with the 3-D dictionary and the conventional 2-D dictionary to compare their efficiencies in representing volumetric images. Then, multiple real data experiments are conducted for performance validation. Based on these results, we found: 1) the 3-D dictionary-based sparse coefficients have three orders narrower Laplacian distribution compared with the 2-D dictionary, suggesting the higher representation efficiencies of the 3-D dictionary; 2) the sparsity level curve demonstrates a clear Z-shape, and hence referred to as Z-curve, in this paper; 3) the parameter associated with the maximum curvature point of the Z-curve suggests a nice parameter choice, which could be adaptively located with the proposed Z-index parameterization (ZIP) method; 4) the proposed 3-DDL algorithm equipped with the ZIP method could deliver reconstructions with the lowest root mean squared errors and the highest structural similarity index compared with the competing methods; 5) similar noise performance as the regular dose FDK reconstruction regarding the standard deviation metric could be achieved with the proposed method using (1/2)/(1/4)/(1/8) dose level projections. The contrast-noise ratio is improved by ~2.5/3.5 times with respect to two different cases under the (1/8) dose level compared with the low dose FDK reconstruction. The proposed method is expected to reduce the radiation dose by a factor of 8 for CBCT, considering the voted strongly discriminated low contrast tissues.

Indexed as

Machine LearningAlgorithmsCone-Beam Computed TomographyDatabases, FactualFemaleHeadHumansImage Processing, Computer-AssistedMaleProstate

Identifiers

PMID28981411
PMCPMC5732496

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.