Evidence map›Paper›PMID 28979094›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2017

Ocular parameters before and after steep Trendelenburg positioning for robotic-assisted laparoscopic radical prostatectomy.

Kyoichi Mizumoto, Masahiko Gosho, Masayoshi Iwaki, Masahiro Zako

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Challenges for anaesthesia for robotic-assisted surgery in the elderly: A narrative review.European journal of anaesthesiology and intensive care · 2023
    Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Kyoichi MizumotoDepartment of Ophthalmology, Aichi Medical University, Nagakute, Aichi, Japan.
Masahiko GoshoDepartment of Clinical Trial and Clinical Epidemiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Masayoshi IwakiDepartment of Ophthalmology, Aichi Medical University, Nagakute, Aichi, Japan.
Masahiro ZakoDepartment of Ophthalmology, Asai Hospital, Seto, Aichi, Japan.
Aichi Medical University · JPUniversity of Tsukuba · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIntraocular pressure (IOP) increases in patients in a steep Trendelenburg position during robotic-assisted laparoscopic radical prostatectomy (RALP). We hypothesized that a steep Trendelenburg position during RALP, an unusual systemic condition involving a transiently increased IOP, may induce ocular pathology that can be detected by detailed evaluations long after the surgery. This study aims to explore ocular structural and functional parameters in patients before and in the long term after the surgery. PATIENTS AND

methodsA comparative observational study was performed. A total of 44 eyes of 22 male patients scheduled for RALP at Aichi Medical University from August 2012 to July 2013 were included. Clinical parameters before and after RALP were compared. Perioperative IOP was measured immediately post-induction of anesthesia in the flat supine position (T1), immediately post-steep Trendelenburg position (T2), and prior to returning to a flat supine position while in a steep Trendelenburg position (T3). The thicknesses of the peripapillary retinal nerve fiber layer, ganglion cell complex (GCC), and central fovea were measured with spectral domain optical coherence tomography. Humphrey perimetry was performed before and at 3 and 6 months after surgery.

resultsThe average IOPs (mmHg) at each stage were T1=10.4, T2=21.7, and T3=29.6, and differed significantly. The mean visual acuity (logarithm of the minimal angle of resolution), IOP, mean deviation, and pattern standard deviation measured by the Humphrey field analyzer showed no statistically significant difference before and after surgery. The ganglion cell complex and retinal nerve fiber layer thicknesses measured at each location and the central fovea thicknesses measured before and after surgery did not differ significantly.

conclusionNo significant disorders in ocular structural and functional parameters were found until long after RALP.

Indexed as

Humphrey perimetryretinal nerve fiber layerrobotic-assisted laparoscopic radical prostatectomyspectral domain optical coherence tomographysteep Trendelenburg position

Identifiers

PMID28979094
PMCPMC5602464
OpenAlexW2756029353

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.