ArticleClinical ophthalmology (Auckland, N.Z.)2017
Ocular parameters before and after steep Trendelenburg positioning for robotic-assisted laparoscopic radical prostatectomy.
Article in Clinical ophthalmology (Auckland, N.Z.), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 13 citations in OpenAlex.
- Postoperative Patient-Reported Visual Symptoms After Robot-Assisted Laparoscopic Radical Prostatectomy in Steep Trendelenburg: A Prospective Single-Center Observational Cohort Study.Life (Basel, Switzerland) · 2026Article
- Challenges for anaesthesia for robotic-assisted surgery in the elderly: A narrative review.European journal of anaesthesiology and intensive care · 2023Review
- Perioperative Care of the Patient with Eye Pathologies Undergoing Nonocular Surgery.Anesthesiology · 2022Article
- The Impact of Steep Trendelenburg Position on Intraocular Pressure.Journal of clinical medicine · 2022Review
- Quantitative rise in intraocular pressure in patients undergoing robotic surgery in steep Trendelenburg position: A prospective observational study.Journal of anaesthesiology, clinical pharmacologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIntraocular pressure (IOP) increases in patients in a steep Trendelenburg position during robotic-assisted laparoscopic radical prostatectomy (RALP). We hypothesized that a steep Trendelenburg position during RALP, an unusual systemic condition involving a transiently increased IOP, may induce ocular pathology that can be detected by detailed evaluations long after the surgery. This study aims to explore ocular structural and functional parameters in patients before and in the long term after the surgery. PATIENTS AND
methodsA comparative observational study was performed. A total of 44 eyes of 22 male patients scheduled for RALP at Aichi Medical University from August 2012 to July 2013 were included. Clinical parameters before and after RALP were compared. Perioperative IOP was measured immediately post-induction of anesthesia in the flat supine position (T1), immediately post-steep Trendelenburg position (T2), and prior to returning to a flat supine position while in a steep Trendelenburg position (T3). The thicknesses of the peripapillary retinal nerve fiber layer, ganglion cell complex (GCC), and central fovea were measured with spectral domain optical coherence tomography. Humphrey perimetry was performed before and at 3 and 6 months after surgery.
resultsThe average IOPs (mmHg) at each stage were T1=10.4, T2=21.7, and T3=29.6, and differed significantly. The mean visual acuity (logarithm of the minimal angle of resolution), IOP, mean deviation, and pattern standard deviation measured by the Humphrey field analyzer showed no statistically significant difference before and after surgery. The ganglion cell complex and retinal nerve fiber layer thicknesses measured at each location and the central fovea thicknesses measured before and after surgery did not differ significantly.
conclusionNo significant disorders in ocular structural and functional parameters were found until long after RALP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials