Evidence map›Paper›PMID 28975080›Full record

ArticleAnesthesiology and pain medicine2016

Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report.

Naomi Ono, Junko Nakahira, Sayuri Matsunami, Toshiyuki Sawai, Toshiaki Minami

Open access · hybridAbstract readCase Reports
In one paragraph

Article in Anesthesiology and pain medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Naomi OnoDepartment of Anesthesiology, Osaka Medical College, Takatsuki, Japan.
Junko NakahiraDepartment of Anesthesiology, Osaka Medical College, Takatsuki, Japan.
Sayuri MatsunamiDepartment of Anesthesiology, Osaka Medical College, Takatsuki, Japan.
Toshiyuki SawaiDepartment of Anesthesiology, Osaka Medical College, Takatsuki, Japan.
Toshiaki MinamiDepartment of Anesthesiology, Osaka Medical College, Takatsuki, Japan.
Osaka Medical and Pharmaceutical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct the catheter placement. CASE PRESENTATION: A 74-year-old male underwent mitral valve plasty for cardiac failure caused by mitral valve regurgitation. Preoperative transthoracic echocardiography showed no septal shunt. The pulmonary artery was catheterized through a sheath introducer in the right jugular vein, and the balloon was inflated after insertion of a 15-cm catheter. The catheter was advanced until a pulmonary artery waveform was detected and the pulmonary artery wedge pressure was 21 mmHg at end-expiration. The balloon was deflated and the catheter tip was pulled back 3 cm. Pulmonary artery waveforms and appropriate a and v waves were detected, and transesophageal echocardiography confirmed the location of the catheter tip in the right pulmonary artery. The first collected blood sample had an oxygen partial pressure of 358.8 mmHg, carbon dioxide partial pressure of 20.1 mmHg, and oxygen saturation of 99%, indicating pulmonary venous blood. The pulmonary artery catheter was pulled back 5 cm, but a second blood sample showed the same results. The catheter was pulled back a further 6 cm while the location of the catheter tip was monitored on X-ray fluoroscopy. Blood gas testing through the catheter tip showed oxygen saturation of 84.4 % and oxygen partial pressure of 41.6 mmHg. Surgery was performed uneventfully. Postoperative chest radiographs showed proper placement of the pulmonary artery catheter, but radiographs on postoperative day 1 showed over-insertion, although the insertion length was unchanged. The catheter was removed. The patient was discharged 2 months postoperatively.

conclusionsOur case highlights the fact that the tip of the pulmonary artery catheter can easily advance into a peripheral branch of the pulmonary artery and cause pulmonary venous blood to be sampled instead of pulmonary arterial blood. A variety of monitoring techniques are needed to confirm accurate catheter placement.

Indexed as

Blood SamplingCase ReportPulmonary ArteryPulmonary Artery Catheter

Identifiers

PMID28975080
PMCPMC5560641
OpenAlexW2537986799

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.