ArticleJournal of biomedical optics2017
Wavelength-coded volume holographic imaging endoscope for multidepth imaging.
Article in Journal of biomedical optics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Line-scan chromatic confocal microscopy for multi-depth imaging of skin tissue using deconvolution.Biomedical optics express · 2025Article
- Speckle illumination holographic non-scanning fluorescence endoscopy.Journal of biophotonics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A wavelength-coded volume holographic imaging (WC-VHI) endoscope system capable of simultaneous multifocal imaging is presented. The system images light from two depths separated by 100 μm in a tissue sample by using axial chromatic dispersion of a gradient index probe in combination with two light-emitting diode sources and a multiplexed volume hologram to separate the images. This system is different from previous VHI systems in that it uses planar multiplexed gratings and does not require curved holographic gratings. This results in improved lateral imaging resolution from 228.1 to 322.5 lp/mm. This letter describes the design and fabrication of the WC-VHI endoscope and experimental images of hard and soft resolution targets and biological tissue samples to illustrate the performance properties.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.