ArticleMagnetic resonance in medicine2018
Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR.
Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- PET/MRI in colorectal and anal cancers: an update.Abdominal radiology (New York) · 2023Review
- Correction of BNMR in biomedicine · 2023Article
- Characterization of hardware-related spatial distortions for IR-PETRA pulse sequence using a brain specific phantom.Magma (New York, N.Y.) · 2021Article
- Attenuation correction for human PET/MRI studies.Physics in medicine and biology · 2020Article
- Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study.NMR in biomedicine · 2020Article
- MR Image-Based Attenuation Correction of Brain PET Imaging: Review of Literature on Machine Learning Approaches for Segmentation.Journal of digital imaging · 2020Review
- Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI.IEEE transactions on medical imaging · 2020Article
- MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition.Medical physics · 2020Article
- Inversion recovery zero echo time (IR-ZTE) imaging for direct myelin detection in human brain: a feasibility study.Quantitative imaging in medicine and surgery · 2020Article
- Inversion recovery UTE based volumetric myelin imaging in human brain using interleaved hybrid encoding.Magnetic resonance in medicine · 2020Article
- PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques.Medical physics · 2020Review
- Fat suppression for ultrashort echo time imaging using a single-point Dixon method.NMR in biomedicine · 2019Article
- Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study.Magnetic resonance in medicine · 2019Article
- True phase quantitative susceptibility mapping using continuous single-point imaging: a feasibility study.Magnetic resonance in medicine · 2019Article
- A deep learning approach forEJNMMI physics · 2018Article
- Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images.Tomography (Ann Arbor, Mich.) · 2018Article
- Technical Note: Deep learning based MRAC using rapid ultrashort echo time imaging.Medical physics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeIn this study, we propose a rapid acquisition for MR-based attenuation correction (MRAC) in positron emission tomography (PET)/MR imaging, in which an ultrashort echo time (UTE) image and an out-of-phase echo image are obtained within a single rapid scan (35 s) at high spatial resolution (1 mm
methodsIn dual-echo ramped hybrid encoding (dRHE), a UTE echo is directly followed by a second out-of-phase echo, in which hybrid spatial encoding combining single-point imaging and 3-dimensional radial frequency encoding is used to improve the quality of both images. Two-point Dixon reconstruction is used to estimate fat- and water-separated images, and UTE images are used to estimate bone. Air and bone segmentation is improved by using multiple UTE images with an advanced hybrid-encoding scheme that allows reconstruction of multiple UTE images. To evaluate the proposed method, dRHE-MRAC PET/MR brain imaging was performed in 10 subjects. Dice coefficients and PET reconstruction errors relative to CT-based attenuation correction were compared with existing system MRAC approaches.
resultsIn dRHE-MRAC, the Dice coefficients for soft tissue, air, and bone were respectively 0.95 ± 0.01, 0.62 ± 0.06, and 0.78 ± 0.05, which was a significantly improved result compared with existing approaches. In most brain regions, dRHE-MRAC showed significantly reduced PET error (less than 1%) with P values less than 0.05.