Evidence map›Paper›PMID 28971512›Full record

ArticleMagnetic resonance in medicine2018

Reduced acoustic noise in diffusion tensor imaging on a compact MRI system.

Ek T Tan, Christopher J Hardy, Yunhong Shu, Myung-Ho In, Arnaud Guidon, John Huston, Matt A Bernstein, Thomas K F Foo

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ek T TanGE Global Research, Niskayuna, New York, USA.ORCID 0000-0003-2847-9378
Christopher J HardyGE Global Research, Niskayuna, New York, USA.
Yunhong ShuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Myung-Ho InDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Arnaud GuidonGE Healthcare, Boston, Massachusetts, USA.
John HustonDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Matt A BernsteinDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-3770-0441
Thomas K F FooGE Global Research, Niskayuna, New York, USA.

Funding

High Performance, Highly Deployable Head-Only MRI ScannerR01EB010065 · NIBIB · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2010 to 2015
$5.5M
High-performance compact 3T MRI: Technical optimization for advanced brain imagingU01EB024450 · NIBIB · MAYO CLINIC ROCHESTER · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2017 to 2021
$5.3M
NIBIB NIH HHS R01 EB010065NIBIB NIH HHS U01 EB024450
6 · The paper itself

Abstract

purposeTo investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42-cm inner-diameter asymmetric gradient.

methodsA-weighted acoustic measurements were made using 10 mT/m-amplitude sinusoidal waveforms, corresponding to echo-planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole-body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient-derating corresponding to multi- and single-shot acquisitions, respectively.

resultsSinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A-weighted decibels (dBA) on average as compared to the whole-body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non-derated, single-shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%).

conclusionThe feasibility of achieving reduced acoustic noise levels with whole-brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902-2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Indexed as

Diffusion Magnetic Resonance ImagingDiffusion Tensor ImagingAcousticsAdultAnisotropyBrainEcho-Planar ImagingFeasibility StudiesFemaleHumansImage Processing, Computer-AssistedMaleNoisePhantoms, ImagingReproducibility of ResultsSignal-To-Noise Ratiocompact 3Tdiffusion tensor imaginghead-only gradientsilent MRI

Identifiers

PMID28971512
PMCPMC5843507

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.