Evidence map›Paper›PMID 28966566›Full record

ArticleIEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society2017

Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

Junhyoung Ha, Frank C Park, Pierre E Dupont

Abstract read
In one paragraph

Article in IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. A Telescopic Tendon-Driven Needle Robot for Minimally Invasive Neurosurgery.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2023
    Article
  2. Continuum Robots for Medical Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  3. Article
  4. Eccentric Tube Robots as Multiarmed Steerable Sheaths.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022
    Article
  5. Article
  6. Modeling Tube Clearance and Bounding the Effect of Friction in Concentric Tube Robot Kinematics.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2019
    Article
  7. Toward the Design of Personalized Continuum Surgical Robots.Annals of biomedical engineering · 2018
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Junhyoung HaDepartment of Cardiovascular Surgery, Boston Childrens Hospital, Harvard Medical School, Boston, MA 02115 USA.
Frank C ParkSchool of Mechanical Engineering, Seoul National University.
Pierre E DupontDepartment of Cardiovascular Surgery, Boston Childrens Hospital, Harvard Medical School.

Funding

Cardioscopically-guided Valve Repair in the Beating HeartR01HL124020 · NHLBI · BOSTON CHILDREN'S HOSPITAL · PI Pierre E Dupont · 2014 to 2026
$9.7M
NHLBI NIH HHS R01 HL124020
6 · The paper itself

Abstract

Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

Indexed as

Concentric tube robotelastic stabilityoptimal designprecurvature

Identifiers

PMID28966566
PMCPMC5614523

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.