ArticleNeuroImage2017
Towards quantification of myelin by solid-state MRI of the lipid matrix protons.
Article in NeuroImage, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 50 citations in OpenAlex.
- Three-Dimensional Efficient Myelin-Weighted Imaging Utilizing Direct Visualization of Short Transverse Relaxation Time Component (ViSTa).Human brain mapping · 2025Article
- Brain short TNeuroImage · 2025Article
- UTE MRI technical developments and applications in osteoporosis: a review.Frontiers in endocrinology · 2025Review
- Article
- 3D inversion recovery ultrashort echo time MRI can detect demyelination in cuprizone-treated mice.Frontiers in neuroimaging · 2024Article
- Quantitative magnetic resonance mapping of the myelin bilayer reflects pathology in multiple sclerosis brain tissue.Science advances · 2023Article
- Nonaqueous magnetization following adiabatic and selective pulses in brain: T1 and cross-relaxation dynamics.NMR in biomedicine · 2023Article
- Clinical evaluation of white matter lesions on 3D inversion recovery ultrashort echo time MRI in multiple sclerosis.Quantitative imaging in medicine and surgery · 2023Article
- Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping.Human brain mapping · 2023Article
- Mapping the myelin bilayer with short-TMagnetic resonance in medicine · 2023Article
- Ultra-short TMagnetic resonance in medicine · 2023Article
- Low field slice-selective ZTE imaging of ultra-short [Formula: see text] tissues based on spin-locking.Scientific reports · 2023Article
- Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications.Applied physics reviews · 2022Review
- Prepolarized MRI of hard tissues and solid-state matter.NMR in biomedicine · 2022Article
- Brain ultrashort TJournal of magnetic resonance (San Diego, Calif. : 1997) · 2021Article
- RAFF-4, Magnetization Transfer and Diffusion Tensor MRI of Lysophosphatidylcholine Induced Demyelination and Remyelination in Rats.Frontiers in neuroscience · 2021Article
- Feasibility of an Inversion Recovery-Prepared Fat-Saturated Zero Echo Time Sequence for High Contrast Imaging of the Osteochondral Junction.Frontiers in endocrinology · 2021Article
- Article
- Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging.NMR in biomedicine · 2020Article
- Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI.IEEE transactions on medical imaging · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
purposeDirect assessment of myelin has the potential to reveal central nervous system abnormalities and serve as a means to follow patients with demyelinating disorders during treatment. Here, we investigated the feasibility of direct imaging and quantification of the myelin proton pool, without the many possible confounds inherent to indirect methods, via long-T
methodsZTE and UTE experiments, with and without inversion-recovery (IR) preparation, were conducted in ovine spinal cords before and after D
resultsMR signal amplitudes from reference samples at 9.4T were linearly correlated with myelin concentration (R
conclusionIn the present implementation, IR-UTE at 9.4T produced similar estimates of myelin concentration in D
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.