ArticleJournal of biomedical materials research. Part B, Applied biomaterials2018
Hemocompatibility of hyaluronan enhanced linear low density polyethylene for blood contacting applications.
Article in Journal of biomedical materials research. Part B, Applied biomaterials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 25 citations in OpenAlex.
- Advancements and Perspectives in the Bioprosthetic Heart Valve: A Comprehensive Review on Biomaterial Processing and Emerging Polymeric Materials.Journal of the American Heart Association · 2025Review
- Polymeric Heart Valves: Do They Represent a Reliable Alternative to Current Prosthetic Devices?Polymers · 2025Review
- Early Feasibility Study of a Hybrid Tissue-Engineered Mitral Valve in an Ovine Model.Journal of cardiovascular development and disease · 2024Article
- Polymeric Heart Valves Will Displace Mechanical and Tissue Heart Valves: A New Era for the Medical Devices.International journal of molecular sciences · 2023Review
- Blood Coagulation on Titanium Dioxide Films with Various Crystal Structures on Titanium Implant Surfaces.Cells · 2022Article
- Natural Polymers in Heart Valve Tissue Engineering: Strategies, Advances and Challenges.Biomedicines · 2022Review
- Preliminary hemocompatibility assessment of an innovative material for blood contacting surfaces.Journal of materials science. Materials in medicine · 2021Article
- Evaluating Whole Blood ClottingBio-protocol · 2020Article
- Interaction of blood plasma proteins with superhemophobic titania nanotube surfaces.Nanomedicine : nanotechnology, biology, and medicine · 2019Article
- In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.Journal of the mechanical behavior of biomedical materials · 2019Article
- An Effective Translation: The Development of Hyaluronan-Based Medical Products From the Physicochemical, and Preclinical Aspects.Frontiers in bioengineering and biotechnology · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Despite their overall success, different blood-contacting medical devices such as heart valves, stents, and so forth, are still plagued with hemocompatibility issues which often result in the need for subsequent replacement and/or life-long anticoagulation therapy. Consequently, there is a significant interest in developing biomaterials that can address these issues. Polymeric-based materials have been proposed for use in many applications due to their ability to be finely tuned through manufacturing and surface modification to enhance hemocompatibility. In this study, we have developed a novel, hydrophilic biomaterial comprised of an interpenetrating polymer network (IPN) of hyaluronan (HA) and linear low density polyethylene (LLDPE). HA is a highly lubricous, anionic polysaccharide ubiquitously found in the human body. It is currently being investigated for a vast array of biomedical applications including cardiovascular therapies such as hydrogel-based regenerative cell therapies for myocardial infarction, HA-coated stents, and surface modifications of polyurethane and metals for use in blood-contacting implants. The aim of this study was to assess the in vitro thrombogenic response of the hydrophilic polymer surface, HA-LLDPE for future potential use as flexible heart valve leaflets. The results indicate that HA-LLDPE is non-toxic and reduces thromobogenicity as compared to LLDPE surfaces, asserting its feasibility for use as a blood-contacting biomaterial. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1964-1975, 2018.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.