Evidence map›Paper›PMID 28963506›Full record

ArticleScientific reports2017

X-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter.

James Archer, Enbang Li, Marco Petasecca, Andrew Dipuglia, Matthew Cameron, Andrew Stevenson, Chris Hall, Daniel Hausermann, Anatoly Rosenfeld, Michael Lerch

Abstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

James ArcherCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.ORCID 0000-0002-8954-2521
Enbang LiCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia. enbang@uow.edu.au.
Marco PetaseccaCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.
Andrew DipugliaCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.
Matthew CameronCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.
Andrew StevensonImaging and Medical Beam-Line, Australian Synchrotron, VIC, 3168, Australia.ORCID 0000-0002-0691-6883
Chris HallImaging and Medical Beam-Line, Australian Synchrotron, VIC, 3168, Australia.
Daniel HausermannImaging and Medical Beam-Line, Australian Synchrotron, VIC, 3168, Australia.
Anatoly RosenfeldCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.
Michael LerchCentre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Synchrotron microbeam radiation therapy is a novel external beam therapy under investigation, that uses highly brilliant synchrotron x-rays in microbeams 50 μm width, with separation of 400 μm, as implemented here. Due to the fine spatial fractionation dosimetry of these beams is a challenging and complicated problem. In this proof-of-concept work, we present a fibre optic dosimeter that uses plastic scintillator as the radiation conversion material. We claim an ideal one-dimensional resolution of 50 μm. Using plastic scintillator and fibre optic makes this dosimeter water-equivalent, a very desirable dosimetric property. The dosimeter was tested at the Australian Synchrotron, on the Imaging and Medical Beam-Line. The individual microbeams were able to be resolved and the peak-to-valley dose ratio and the full width at half maximum of the microbeams was measured. These results are compared to a semiconductor strip detector of the same spatial resolution. A percent depth dose was measured and compared to data acquired by an ionisation chamber. The results presented demonstrate significant steps towards the development of an optical dosimeter with the potential to be applied in quality assurance of microbeam radiation therapy, which is vital if clinical trials are to be performed on human patients.

Identifiers

PMID28963506
PMCPMC5622140

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.