Evidence map›Paper›PMID 28960036›Full record

ArticleJournal of Korean medical science2017

Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis.

Eun Mi Yang, Eujin Park, Yo Han Ahn, Hyun Jin Choi, Hee Gyung Kang, Hae Il Cheong, Il Soo Ha

Open access · goldAbstract read
In one paragraph

Article in Journal of Korean medical science, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 32 citations in OpenAlex.

  1. Bioelectrical Impedance in Pediatric Dialysis: Clinical Applications, Limitations, and Opportunities.Hemodialysis international. International Symposium on Home Hemodialysis · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. In-Season Body Composition Effects in Professional Women Soccer Players.International journal of environmental research and public health · 2021
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Eun Mi YangDepartment of Pediatrics, Chonnam National University Hospital, Gwangju, Korea.ORCID https://orcid.org/0000-0001-9410-5855
Eujin ParkDepartment of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-4413-468X
Yo Han AhnDepartment of Pediatrics, Hallym University Kangnam Sacred Heart Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-8185-4408
Hyun Jin ChoiDepartment of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-5473-0058
Hee Gyung KangDepartment of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea. pedneph@snuh.org.ORCID https://orcid.org/0000-0001-8323-5320
Hae Il CheongDepartment of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-7556-1265
Il Soo HaDepartment of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-5428-6209
Seoul National University Children's Hospital · KRChonnam National University Hospital · KRHallym University Kangnam Sacred Heart Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Adequate fluid management is an important therapeutic goal of dialysis. Recently, bioelectrical impedance methods have been used to determine body fluid status, but pediatric reports are rare. To determine the accuracy of bioelectrical impedance methods in the assessment of body fluid statusof children undergoing hemodialysis (HD), 12 children on HD were studied. A multi-frequency bioimpedance analysis device (Inbody S10) and bioimpedance spectroscopy device (BCM) were used to evaluate fluid status. Fluid removal during a HD session (assessed as body-weight change, ΔBWt) was compared with the difference in total body water determined by each device (measured fluid difference, ΔMF), which showed strong correlation using either method (Pearson's coefficient, r = 0.772 with Inbody S10 vs. 0.799 with BCM). Bioimpedance measurement indicated fluid overload (FO; ΔHS greater than 7%) in 34.8% with Inbody S10 and 56.5% with BCM, and only about 60% of children with FO by bioimpedance methods showed clinical symptoms such as hypertension and edema. In some patients with larger weight gain Inbody S10-assessed overhydration (OH) was much smaller than BCM-assessed OH, suggesting that BCM is more relevant in estimating fluid accumulation amount than Inbody S10. To our knowledge, this is the first report on the use of body composition monitors to assess fluid status in Korean children receiving HD.

Indexed as

Electric ImpedanceRenal DialysisAdolescentBody CompositionBody WeightChildChild, PreschoolEdemaFemaleHumansHypertensionMaleOrganism Hydration StatusYoung AdultBioimpedanceChildrenFluid StatusHemodialysis

Identifiers

PMID28960036
PMCPMC5639064
OpenAlexW2759065438

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.